With NCM-MCI-6.10 study tool, you no longer need to look at a drowsy textbook. You do not need to study day and night. With NCM-MCI-6.10 learning dumps, you only need to spend 20-30 hours on studying, and then you can easily pass the exam. At the same time, the language in NCM-MCI-6.10 test question is very simple and easy to understand. Even if you are a newcomer who has just entered the industry, you can learn all the knowledge points without any obstacles. We believe that NCM-MCI-6.10 Study Tool will make you fall in love with learning. Come and buy it now.
| Section | Objectives |
|---|---|
| Topic 1: Analyze and Optimize Network Performance | - Advanced network configuration - Flow policies analysis and optimization - Overlay networking optimization - Physical and virtual network evaluation |
| Topic 2: Business Continuity | - BCDR compliance analysis - Workload resilience evaluation |
| Topic 3: Advanced Configuration and Troubleshooting | - Security posture analysis - Third-party integrations - CLI and API execution - Risk mitigation configuration - Troubleshooting Nutanix services |
| Topic 4: Analyze and Optimize Storage Performance | - Storage internals and I/O analysis - Storage configuration optimization - Workload performance evaluation |
| Topic 5: Analyze and Optimize VM Performance | - VM resource optimization - Cluster and node metrics analysis |
>> Reliable NCM-MCI-6.10 Exam Simulations <<
Based on high-quality products, our NCM-MCI-6.10 guide torrent has high quality to guarantee your test pass rate, which can achieve 98% to 100%. NCM-MCI-6.10 study tool is updated online by our experienced experts, and then sent to the user. And we provide free updates of NCM-MCI-6.10 training material for one year after your payment. The data of our NCM-MCI-6.10 Exam Torrent is forward-looking and can grasp hot topics to help users master the latest knowledge. And you can also free download the demo of NCM-MCI-6.10 exam questions to have a check.
NEW QUESTION # 28
An administrator needs to perform AOS and AHV upgrades on a Nutanix cluster and wants to ensure that VM data is replicated as quickly as possible when hosts and CVMs are rebooted.
Configure Cluster 1 so that after planned host and CVM reboots, the rebuild scan starts immediately.
Note:
You will need to use SSH for this task. Ignore the fact that this is a 1-node cluster.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure the immediate rebuild scan on Cluster 1.
This task must be performed from an SSH session connected to a CVM (Controller VM) on Cluster 1.
1. Access the Cluster 1 CVM
* From the Prism Central dashboard, navigate to Hardware > Clusters and click on Cluster 1 to open its Prism Element (PE) interface.
* In the Cluster 1 PE, navigate to Hardware > CVMs to find the IP address of any CVM in the cluster.
* Use an SSH client (like PuTTY) to connect to the CVM's IP address.
* Log in with the admin user and password.
2. Modify the Rebuild Delay Setting
By default, the cluster waits 15 minutes (900 seconds) before starting a rebuild scan after a CVM reboot. You will change this setting to 0.
* Once logged into the CVM, run the following command to set the delay to 0 seconds:
gflag --set --gflags=stargate_delayed_rebuild_scan_secs=0
* (Optional but recommended) You can verify the change took effect by running the "get" command:
gflag --get --gflags=stargate_delayed_rebuild_scan_secs
The output should now show stargate_delayed_rebuild_scan_secs=0.
NEW QUESTION # 29
Use Prism Element for this question.
The Application team has a 3 tier application (App Server, Web Server, and Database Server) that is mission critical and requires as close to 0 RPO and RTO as possible with their current license level.
The organization has 2 clusters, with one cluster (Cluster 1) being production and the other cluster (Cluster 2) being remote/DR. Cluster 2 should be able to fail back to Cluster 1.
The connectivity between the two sites is >5ms and replication traffic should not use more than 10Mbps of bandwidth. The Application team requests a plan that includes the ability to go back 2 days locally, and 2 days remotely.
The team also requests that all 3 VMs be treated as a single group and backed up collectively in a snapshot.
The three VMs are:
* Web-Prod
* App-Prod
* DB-Prod
Use Task3 as part of the name for any objects created for this task.
Note: VMs do NOT need to be powered on. You will need to use the 172.30.0.x IP addresses when configuring DR.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure Disaster Recovery from the Cluster 1 Prism Element interface.
1. Add Cluster 2 as a Remote Site
First, you must register Cluster 2 as a DR target for Cluster 1.
* From the Cluster 1 Prism Element dashboard, navigate to Data Protection from the main dropdown menu.
* Click the Remote Site tab.
* Click the + Remote Site button and select Physical Cluster.
* In the "Name" field, enter Cluster2_DR_Task3.
* In the "Address" field, enter the 172.30.0.x Virtual IP address of Cluster 2.
* Click Save. The clusters will exchange credentials and connect.
2. Throttle Replication Bandwidth
Next, apply the 10 Mbps bandwidth limit for traffic going to Cluster 2.
* On the same Remote Site tab, select the newly created Cluster2_DR_Task3.
* Click the Update button.
* In the dialog, set the Bandwidth Limit to 10 Mbps.
* Click Save.
3. Create the Protection Domain
A Protection Domain (PD) is the top-level object that will manage the VMs and replication schedules.
* In the Data Protection dashboard, click the Table tab.
* Click the + Protection Domain button and select Async DR.
* For the Name, enter App_PD_Task3.
* Click Create.
4. Protect VMs in a Consistency Group
Now you will add the three application VMs to the new Protection Domain as a single Consistency Group (CG).
* You will be taken to the dashboard for the new App_PD_Task3. In the Entities panel, click the Protect Entities button.
* In the "Protect Entities" dialog, search for and select the three VMs:
* Web-Prod
* App-Prod
* DB-Prod
* Click Next.
* Select Create new consistency group and name it App_CG_Task3.
* Click Protect.
5. Create the Replication Schedule
Finally, configure the schedule to meet the RPO and retention requirements.
* In the App_PD_Task3 dashboard, click the Schedules tab.
* Click the + New Schedule button.
* Remote Site: Select Cluster2_DR_Task3.
* RPO (Repeat every): Select NearSync. Set the RPO to 1 minute.
* Note: This is the lowest possible RPO for an Async (>5ms latency) connection, fulfilling the "as close to 0" requirement.
* Local Retention: Set to 2 Days.
* Remote Retention: Set to 2 Days.
* Ensure the "Store snapshots for 2-way replication" checkbox is enabled to allow failback from Cluster 2.
* Click Create Schedule.
NEW QUESTION # 30
Task 16
An administrator is working to create a VM using Nutanix V3 API calls with the following specifications.
* VM specifications:
* vCPUs: 2
* Memory: BGb
* Disk Size: 50Gb
* Cluster: Cluster A
* Network: default- net
The API call is falling, indicating an issue with the payload:
The body is saved in Desktop/ Files/API_Create_VM,text
Correct any issues in the text file that would prevent from creating the VM. Also ensure the VM will be created as speeded and make sure it is saved for re-use using that filename.
Deploy the vm through the API
Note: Do not power on the VM.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
https://portal.nutanix.com/page/documents/kbs/details?targetId=kA00e000000LLEzCAO
https://jsonformatter.curiousconcept.com/#
acli net.list (uuid network defult_net)
ncli cluster info (uuid cluster)
Put Call: https://Prism Central IP address : 9440/api/nutanix/v3vms
Edit these lines to fix the API call, do not add new lines or copy lines.
You can test using the Prism Element API explorer or PostMan
Body:
{
{
"spec": {
"name": "Test_Deploy",
"resources": {
"power_state":"OFF",
"num_vcpus_per_socket": ,
"num_sockets": 1,
"memory_size_mib": 8192,
"disk_list": [
{
"disk_size_mib": 51200,
"device_properties": {
"device_type":"DISK"
}
},
{
"device_properties": {
"device_type":"CDROM"
}
}
],
"nic_list":[
{
"nic_type": "NORMAL_NIC",
"is_connected": true,
"ip_endpoint_list": [
{
"ip_type": "DHCP"
}
],
"subnet_reference": {
"kind": "subnet",
"name": "default_net",
"uuid": "00000000-0000-0000-0000-000000000000"
}
}
],
},
"cluster_reference": {
"kind": "cluster",
"name": "NTNXDemo",
"uuid": "00000000-0000-0000-0000-000000000000"
}
},
"api_version": "3.1.0",
"metadata": {
"kind": "vm"
}
}
https://www.nutanix.dev/2019/08/26/post-a-package-building-your-first-nutanix-rest-api-post-request/ Reference
NEW QUESTION # 31
TASK 1
A newly created Windows VM "SQL02" is experiencing poor storage performance when compared to
"SQL01" running within the same cluster, on the same storage container.
The cluster is in a healthy state.
Create a new session named Monitor SQL02 with meaningful metrics. Right click on the session page and click Select All then paste this into Notepad and save it as Task 1.txt on the desktop.
Also, save the analysis as a report named MonitorSQL02 and send the report as a PDF on a daily basis to perf_group@ACME.org. Reports should not be retained. If any new objects need to be created, use monitovm2 in the name.
Finally, correct the issue within "SQL02".
Notes:
* Do not power on the VMs.
* While you will be creating a session, you will need to examine the VM configurations to determine the issue.
* Do not delete the VM to resolve the issue, any other destructive change is acceptable.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to all three tasks, performed within the Nutanix Prism interface.
Task 1: Create Monitoring Session & Save Metrics
* From the Prism Central dashboard, navigate to Operations > Analysis.
* Click the + New Session button.
* Name the session Monitor SQL02.
* In the "Entities" search box, type SQL01 and select VM: SQL01.
* In the "Entities" search box, type SQL02 and select VM: SQL02.
* Click Add Charts > New Chart.
* Title: Storage IOPS
* Metric: Storage Controller IOPS
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Latency
* Metric: Storage Controller Latency
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Bandwidth
* Metric: Storage Controller Bandwidth
* Click Add.
* Click Save Session.
* With the "Monitor SQL02" session open, right-click anywhere on the page and click Select All.
* Right-click again and select Copy.
* Open Notepad, paste the content, and save the file to the desktop as Task 1.txt.
(The content pasted into Task 1.txt would be the session's chart configurations, showing metrics for SQL01 and SQL02.)
Task 2: Create and Schedule the Report
* While still in the "Monitor SQL02" analysis session, click the Save as Report button (it looks like a bookmark icon).
* Name the report MonitorSQL02 and click Save.
* Navigate to Operations > Reports.
* Find the MonitorSQL02 report in the list. Select its checkbox.
* Click the Actions dropdown and select Schedule.
* Configure the schedule with the following settings:
* Schedule Name: monitovm2_daily_report
* Recurrence: Daily
* Start Time: (Set to a time, e.g., 8:00 AM)
* Repeat every: 1 day(s)
* Retention Policy: Uncheck the "Retain a copy of the report" box. (This ensures reports are not retained).
* Email Report: Check this box.
* Format: PDF
* Recipients: perf_group@ACME.org
* Click Save.
Task 3: Identify and Correct the Performance Issue
This task is performed without powering on the VMs, indicating a configuration error.
Investigation
* Navigate to VMs > Table view.
* Click on the SQL01 (the good VM) and select the Configuration tab.
* Expand the Disks section. Observe that the primary disk is attached to a SCSI bus (e.g., scsi.0). This is the high-performance standard.
* Return to the VM list and click on SQL02 (the problem VM).
* Expand the Disks section.
Root Cause
You discover that the primary disk for SQL02 is attached to an IDE bus. The IDE bus has significant performance limitations and is not suitable for a database server, causing the poor storage performance.
Correction
* With the SQL02 VM selected, click the Update button.
* In the "Update VM" dialog, scroll down to the Disks section.
* Find the disk attached to the IDE bus. Click the Edit (pencil) icon for that disk.
* Change the Bus Type dropdown from IDE to SCSI.
* The Device Index will automatically populate (e.g., scsi.0).
* Click Save in the "Update Disk" dialog.
* (Note: A "VirtIO SCSI Controller" will be automatically added to the VM configuration if one was not already present.)
* Click Save in the "Update VM" dialog.
The VM SQL02 is now configured to use the high-performance VirtIO-SCSI controller, which will resolve the storage performance discrepancy once the VM is powered on.
NEW QUESTION # 32
Create a VM template on Cluster 1 named Small Template that matches the small VM Configuration in NVD-2031 (see the Files\Documentation 6.10 folder) however, you will use default storage container.
Configure SMTP Alerting and NCC reports per NVD-2031 for Cluster 1.
Settings:
* SMTP: Use Cluster 2 IP address
* Cluster email: cluster1@ACME.org
* Alert emails: primaryalerts@ACME.org, secondaryalerts@ACME.org
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to complete both tasks on Cluster 1.
This solution requires you to first find the IP of Cluster 2 (for the SMTP server) and then perform all configurations within the Prism Element interface for Cluster 1.
Prerequisite: Find Cluster 2 IP
* In Prism Central, navigate to Hardware > Clusters.
* Find Cluster 2 in the list and note its IP Address. You will use this in the steps below.
Task 1: Create the VM Template
* Log in to the Prism Element (PE) interface for Cluster 1. (From PC, go to Hardware > Clusters > click the name "Cluster 1").
* Navigate to the VM view from the main dashboard.
* Click the + Create VM button.
* Fill in the VM details based on the NVD-2031 "Small VM" configuration (e.g., 2 vCPUs, 1 Core per vCPU, 4 GB RAM).
* Name: Small Template
* Compute Details:
* vCPUs: 2
* Number of Cores per vCPU: 1
* Memory: 4 GB
* Scroll down to Storage and click + Add New Disk.
* Operation: Select Clone from Image Service.
* Image: Select any available guest OS image (e.g., a Windows or CentOS image).
* Storage Container: Ensure the default container is selected (as required by the task).
* Click Add.
* Scroll down to Network Adapters (NIC) and click + Add NIC.
* Select any available VLAN/Subnet (e.g., Primary).
* Click Add.
* Click Save. The VM will be created (and remain powered off).
* Find the new Small Template VM in the list. Select its checkbox.
* Click the Actions dropdown and select Convert to Template.
* Confirm the action by clicking OK.
Task 2: Configure SMTP and NCC Reports
* While still in the Cluster 1 Prism Element interface, click the gear icon (Settings) in the top-right corner.
* Select SMTP Server from the left-hand menu.
* Click the Configure button.
* In the "Server Settings" tab, fill in the following:
* Server Address: Enter the Cluster 2 IP Address (which you found in the prerequisite step).
* Port: 25 (leave as default).
* From Email Address: cluster1@ACME.org
* Click Next.
* In the "Email Recipients" tab, click + Add Email Recipient.
* Address: primaryalerts@ACME.org
* Ensure all severities (Critical, Warning, Info) are checked.
* Click Save.
* Click + Add Email Recipient again.
* Address: secondaryalerts@ACME.org
* Ensure all severities are checked.
* Click Save.
* Click Done. A test email will be sent.
* In the main Settings menu, select Alerts and Notifications.
* Scroll to the NCC Health Checks section.
* Check the box labeled Email Nutanix Cluster Check reports to recipients. (This will use the SMTP settings and recipients you just configured).
* Click Save.
NEW QUESTION # 33
......
SWREG payment costs more tax. Especially for part of countries, intellectual property taxation will be collected by your countries if you use SWREG payment for NCM-MCI-6.10 exam test engine. So if you want to save money, please choose PayPal. Here choosing PayPal doesn't need to have a PayPal. In fact here you should have credit card. If you click PayPal payment, it will automatically transfer to credit card payment for NCM-MCI-6.10 Exam Test engine. On the other hands, PayPal have strict restriction for sellers account to keep buyers' benefits, so that you can share worry-free purchasing for NCM-MCI-6.10 exam test engine.
NCM-MCI-6.10 PDF Guide: https://www.passtestking.com/Nutanix/NCM-MCI-6.10-practice-exam-dumps.html