Free update for 365 days for FlashArray-Implementation-Specialist study guide materials is available. That is to say, in the following year, you can get the latest information of the exam for free. Besides, our system will send the latest version of FlashArray-Implementation-Specialist exam dumps to your email automatically. And you just need to receive them and carry on your practice. With the experienced experts to compile FlashArray-Implementation-Specialist Study Guide materials, the quality can be guaranteed. And if you choose us, we will help you pass the exam successfully, and obtaining a certificate isn’t a dream.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
>> FlashArray-Implementation-Specialist Latest Exam Pdf <<
Our users are all over the world and they have completed their exams through the help of our FlashArray-Implementation-Specialist study guide. As you can see the feedbacks from our loyal customers, all of them are grateful to our FlashArray-Implementation-Specialist exam braindumps and become succussful people with the FlashArray-Implementation-Specialist Certification. And what are you waiting for? Just selecting our FlashArray-Implementation-Specialist learning materials, the next one to get an international certificate is you!
NEW QUESTION # 11
Which PCIe slot supports 4-port FC cards on FlashArray//XL?
Answer: A
Explanation:
On the FlashArray//XL, the 4-port Fibre Channel (FC) cards are specifically supported in Slot 8 (and typically Slot 4 depending on configuration depth). The FlashArray//XL chassis (5U) utilizes a significantly different PCIe bus layout compared to the standard 3U FlashArray//X series. While the //X series typically uses Slot 0 or Slot 2 for host connectivity, the //XL architecture reserves the lower-numbered slots (0-3) primarily for backend connectivity (SAS/NVMe-oF) or specific NVRAM modules in certain configurations.
To support the high bandwidth requirements of the 4-port 32Gb FC cards, the //XL chassis provides specific x16 electrical slots. Slot 8 is a designated high-performance slot located in the upper riser section of the controller, making it the correct placement for these dense host I/O cards. Using an incorrect slot such as Slot 2 (often x8 or reserved for other functions in XL) would likely result in the card not being recognized or operating at reduced performance. Therefore, Implementation Engineers must verify the specific "slot map" for the //XL model in the FlashArray//XL Hardware Guide before seating cards, with Slot 8 being the standard supported location for the 4-port FC option among the choices provided.
NEW QUESTION # 12
The Pure Engagement Request (PER) specifies that iSCSI ports ETH2 and ETH3 should be set to 10 Gb/s.
After configuring the ports and connecting them to the SAN, the Implementation Engineer observes that ETH2
/3 are not negotiating and display 0 b/s. The SAN is operating at 40 Gb/s, with support for up to 100 Gb/s.
What should the Implementation Engineer do to resolve this issue and complete the install?
Answer: C
Explanation:
When deploying Ethernet-based storage protocols like iSCSI or NVMe/TCP, establishing a healthy Layer 1 physical connection is the absolute first step. On standard Pure Storage FlashArray controllers (like the //X50 or //X70), the default on-board high-speed ports (ETH2 and ETH3) utilize SFP28 physical cages. These specific ports are hardware-designed to support 10GbE or 25GbE speeds depending on the inserted SFP+ or SFP28 transceiver.
In this scenario, a fundamental physical layer mismatch is occurring. The array ports are attempting to link at
10 Gb/s (using SFP+ optics), but the upstream SAN switch is operating natively at 40 Gb/s (which utilizes a physically larger QSFP+ form factor with four parallel 10G lanes). Auto-negotiation across mismatched optical form factors and lane architectures will almost always fail, resulting in a dead link showing 0 b/s.
An Implementation Engineer cannot magically "force negotiate" a 10G/25G SFP28 port on the array to run at
40G because the physical hardware simply does not support that bandwidth or encoding. Attempting to force the switch side (Option C) will also fail if the physical media doesn't match. The only correct, supported resolution is a hardware intervention: the engineer must replace the transceivers with the appropriate type
. Typically, this involves using a QSFP-to-SFP adapter (QSA) on the switch side, or utilizing a specialized
40G-to-4x10G breakout cable to ensure both ends of the fiber are communicating using the exact same light wavelengths, lane counts, and physical port speeds.
NEW QUESTION # 13
If a Technical Support Engineer (TSE) is not available to perform health checks after an installation, what action should the Implementation Engineer take?
Answer: A
Explanation:
If a Pure Storage Technical Support Engineer (TSE) is unavailable to immediately perform the remote health checks upon the completion of the physical installation, the correct procedure is to verify that Remote Assist (RA) is enabled and update the support case with this information.
Standard operating procedure dictates that the Implementation Engineer must not close the install case until the array has been health-checked and verified by Support. Closing the case (Option B) would signal that the work is complete when the critical validation step is missing, potentially leaving the customer with an unverified system. Emailing the account team (Option A) is helpful for visibility but does not advance the technical workflow required to close the loop.
By confirming RA is open (using purearray remoteassist) and documenting the active session port in the case notes, the Implementation Engineer enables the Support team to perform the health checks asynchronously as soon as a TSE becomes available. This ensures the "handshake" between the onsite engineer and the remote support team is maintained without delaying the engineer's departure from the site, while guaranteeing the array will be validated before final sign-off.
NEW QUESTION # 14
A customer has purchased a FlashArray//XL. What power cables are required in order to connect this array to rack PDUs?
Answer: A
Explanation:
The FlashArray//XL requires 4 x C19/C20 power cables to connect to the rack Power Distribution Units (PDUs).
The FlashArray//XL chassis (5U) is significantly larger and draws more power than the standard FlashArray//X series (3U). It is equipped with four high-capacity Power Supply Units (PSUs) to support the increased thermal and electrical load of the dense DirectFlash Modules and high-performance controllers.
Connector Type: To handle the higher amperage safely, the //XL utilizes IEC C20 inlets on the chassis side (rectangular with horizontal pins) rather than the standard C14 inlets found on most servers. Consequently, the required cables must have a C19 connector (female) to plug into the array and a C20 connector (male) to plug into the PDU (assuming a high-power PDU).
Quantity: Since the chassis has four PSUs for N+2 redundancy, four distinct cables are required. The standard C13/C14 cables (Option A/B) used for lower-wattage IT equipment are physically incompatible and electrically insufficient for the //XL platform.
NEW QUESTION # 15
When installing the first DirectFlash Shelf on a FlashArray//XR2/3, what mezzanine ports are used on the controllers?
Answer: B
Explanation:
When installing the first DirectFlash Shelf (DFS) on a FlashArray//XR2 or //XR3 utilizing the onboard or default mezzanine connectivity, the correct ports to use are ETH6 and ETH9.
Hardware Layout: The FlashArray//XR2 and //XR3 utilize a specific Ethernet Mezzanine (EMEZZ) slot for backend connectivity to NVMe-oF shelves. This card typically enumerates its ports as ETH6 through ETH9 (a 4-port configuration).
Cabling Rule: To maximize physical separation and ensure redundancy across the internal ASIC lanes of the mezzanine card, standard cabling procedures for the first shelf dictate using the outer ports: ETH6 (Port 0) and ETH9 (Port 3).
Redundancy: This configuration (Port 0 and Port 3) is preferred over using adjacent ports (like 6 and 7) to reduce the risk of a single lane cluster failure affecting both connections to the shelf. The second shelf, if added later, would typically utilize the remaining ports (ETH7 and ETH8).
NEW QUESTION # 16
......
To make your review more comfortable and effective, we made three versions of FlashArray-Implementation-Specialist study guide as well as a series of favorable benefits for you. We are concerted company offering tailored services which include not only the newest and various versions of FlashArray-Implementation-Specialist Practice Engine, but offer one-year free updates services with patient staff offering help 24/7. It means that as long as our professionals update the FlashArray-Implementation-Specialist learning quiz, you will receive it for free.