그리고 KoreaDumps FlashArray-Implementation-Specialist 시험 문제집의 전체 버전을 클라우드 저장소에서 다운로드할 수 있습니다: https://drive.google.com/open?id=1fTRYFZpXgsnoWTqOjnOR-p2ZnWHlMBPW
Pure Storage인증사에서 주췌하는 FlashArray-Implementation-Specialist시험은 IT업계에 종사하는 분이시라면 모두 패스하여 자격증을 취득하고 싶으리라 믿습니다. KoreaDumps에서는 여러분이 IT인증자격증을 편하게 취득할수 있게 도와드리는 IT자격증시험대비시험자료를 제공해드리는 전문 사이트입니다. KoreaDumps덤프로 자격증취득의 꿈을 이루세요.
| Certification Vendor: | Pure Storage |
|---|---|
| Exam Name: | Pure Storage Certified FlashArray Implementation Specialist |
| Exam Number: | FAIS |
| Exam Price: | USD $300 |
| Related Certifications: | Pure Storage FlashArray Implementation Specialist Certification |
| Passing Score: | Not publicly disclosed by Pure Storage |
| Real Exam Qty: | 75 |
| Available Languages: | English |
| Certificate Validity Period: | 3 years |
| Exam Duration: | 120 minutes |
| Exam Format: | Multiple Choice (three or four options, one to two correct answers) |
| Sample Questions: | Pure Storage FlashArray-Implementation-Specialist Sample Questions |
| Exam Way: | Online (proctored via examslocal.com) |
| Pre Condition: | Recommended hands-on experience with Pure Storage FlashArray systems. Targeted at internal Pure Storage Support Specialists, Partner Support Specialists with root level access, and Enterprise or Dark Site customers with root level access. |
| Official Syllabus URL: | https://academy.purestorage.com/student/page/2164533-certification-fais |
>> FlashArray-Implementation-Specialist최고품질 시험덤프 공부자료 <<
KoreaDumps는 우수한 IT인증시험 공부가이드를 제공하는 전문 사이트인데 업계에서 높은 인지도를 가지고 있습니다. KoreaDumps에서는 IT인증시험에 대비한 모든 덤프자료를 제공해드립니다. Pure Storage인증 FlashArray-Implementation-Specialist시험을 준비하고 계시는 분들은KoreaDumps의Pure Storage인증 FlashArray-Implementation-Specialist덤프로 시험준비를 해보세요. 놀라운 고득점으로 시험패스를 도와드릴것입니다.시험에서 불합격하면 덤프비용 전액환불을 약속드립니다.
| 주제 | 소개 |
|---|---|
| 주제 1 |
|
| 주제 2 |
|
| 주제 3 |
|
| 주제 4 |
|
질문 # 148
After upgrading Purity during a new installation, which command should an Implementation Engineer run to determine what version of Purity will be loaded at the next boot of the FlashArray?
정답:A
설명:
The command pureboot list is the correct tool to verify which Purity version is designated to load upon the next system reboot.
FlashArray controllers maintain two boot partitions (often referred to as banks) for redundancy and upgrade safety. When an upgrade is performed, the new Purity software image is written to the inactive bank.
* Verification: Running pureboot list displays the status of both boot banks (e.g., Primary and Secondary) and explicitly flags which version is "Running" and which is set for "Next Boot."
* Why it's critical: Just checking the currently running version (using pureversion or purearray list) is insufficient during an upgrade workflow. An engineer must confirm that the boot pointer has successfully switched to the new version before issuing the reboot command. If pureboot list shows the old version as "Next Boot," a reboot would simply reload the current code, indicating the upgrade installation failed or wasn't finalized.
질문 # 149
During a FlashArray//X to FlashArray//XL hardware upgrade, when should the Implementation Engineer insert the DFMd modules into the FlashArray//XL?
정답:A
설명:
Upgrading from a FlashArray//X to a FlashArray//XL involves a significant architectural change, often requiring a data migration or a specific "chassis replacement" workflow known as a Data-in-Place upgrade where the new chassis temporarily acts as an expansion shelf. In this specific procedure, the new FlashArray//XL chassis is not immediately populated with its final drives (DFMDs) before power-on because it first needs to be configured to accept data or join the cluster in a controlled state.
The procedure requires the Implementation Engineer to boot the FlashArray//XL chassis first and configure it into Shelf Mode (SPM). Only after the chassis is successfully running in this mode-effectively acting as a passive SAS/Ethernet attached shelf to the existing controllers-are the DirectFlash Modules (DFMd) inserted.
Inserting them earlier could cause the array to attempt a full boot sequence or initialize a new array instance, complicating the upgrade logic. By waiting until Shelf Mode is confirmed, the engineer ensures that the modules are recognized correctly as part of the migration target resources, allowing Purity to manage the layout and data redistribution correctly from the source array.
=========
질문 # 150
What hardware should the Implementation Engineer find in the upgrade kit in order to perform an //X to //XL NDU?
정답:C
설명:
For a Non-Disruptive Upgrade (NDU) from a FlashArray//X to a FlashArray//XL, the upgrade kit typically contains 4 QSFP cables, 2 Mellanox cards, and 20 DFMD blanks (or modules).
2 Mellanox Cards: The FlashArray//X (source) likely requires the installation of 100GbE RoCE adapters (Mellanox) into its controllers to establish the high-speed replication link with the new FlashArray//XL (which has 100GbE native). One card is installed per //X controller.
4 QSFP Cables: To ensure a redundant, high-bandwidth connection between the two arrays during the data migration phase, 2 cables are used per controller pair (CT0-to-CT0 and CT1-to-CT1), totaling 4 cables.
20 DFMDs (Blanks/Fillers): The FlashArray//X typically holds 20 DirectFlash Modules. The FlashArray//XL chassis has 40 slots. When the 20 data drives are physically moved from the //X to the //XL, the //XL will still have 20 empty slots. These must be filled with DirectFlash blanking modules (DFMD blanks) to maintain proper chassis airflow and thermal pressure. Thus, the kit includes these 20 fillers.
질문 # 151
What command will view NVRAM install and update status?
정답:A
설명:
The command purehw list --all is the correct CLI instruction to view the comprehensive status of all hardware components, including the NVRAM modules.
Command Scope: While purehw list provides a general hardware summary, the --all flag (or specifying --type nvram) ensures that granular details about the NVRAM modules-such as their presence, health status, and firmware/update status-are displayed.
NVRAM Context: In FlashArray models that utilize dedicated NVRAM modules (like the FA-400, //M, or specific //X configurations), these components are critical for write acknowledgement. During an upgrade or installation, verification that these modules are "healthy" and "idle" (not destaging) is mandatory.
Incorrect Options:
purearray list (Option A) displays high-level array attributes like the array name, ID, and overall OS version, but not component-level hardware status.
puredrive list (Option B) is specifically for managing the storage media (SSDs/DirectFlash Modules) and does not report on the non-volatile RAM cache modules housed in the controller or chassis.
질문 # 152
An Implementation Engineer attempts to add a FlashArray to a Fusion fleet but receives an error indicating the array cannot be added. The array appears healthy and is connected to Pure1. What is the most likely cause of this issue?
정답:C
설명:
Pure Fusion is a storage-as-code platform that aggregates multiple physical FlashArrays into a single logical
"fleet" or cloud-like storage pool. A fundamental rule of the Fusion architecture and registration process is that a specific physical FlashArray can only belong to one Fusion fleet at a time. This exclusivity ensures that the management plane (Fusion) has authoritative control over the resources, placement logic, and workload balancing for that array without conflict from another management entity.
When an Implementation Engineer encounters an error adding an array that is otherwise healthy and successfully connected to the Pure1 cloud (which acts as the mediator for Fusion), the most probable cause is that the array remains registered to a previous or different Fusion fleet. This often happens if an array was used in a proof-of-concept (POC), a lab environment, or a previous deployment and was not cleanly deregistered before attempting to add it to the new production fleet.
To resolve this, the engineer must verify the array's registration status in Pure1 or the Fusion control plane.
The array must be explicitly removed or deregistered from the conflicting fleet before it becomes available for claim by the new fleet. While Purity versions are important for compatibility, Fusion supports a range of versions, making "not running the latest " a less likely hard-stop error compared to the binary conflict of existing ownership. Similarly, existing workloads do not prevent an array from joining a fleet; Fusion can often import or manage existing resources depending on the configuration.
=========
질문 # 153
......
FlashArray-Implementation-Specialist최신버전 시험공부자료: https://www.koreadumps.com/FlashArray-Implementation-Specialist_exam-braindumps.html
그리고 KoreaDumps FlashArray-Implementation-Specialist 시험 문제집의 전체 버전을 클라우드 저장소에서 다운로드할 수 있습니다: https://drive.google.com/open?id=1fTRYFZpXgsnoWTqOjnOR-p2ZnWHlMBPW