International Code Council M2 Exam Syllabus Topics:

SectionWeightObjectives
Chimneys & Vents14%- Factory-built chimneys and vents
- Clearances and termination requirements
- Chimney construction and materials
- Vent systems and connections
Exhaust & Ventilation Systems20%- Makeup air systems
- Ventilation rates and outdoor air requirements
- Hazardous and special exhaust systems
- Commercial kitchen exhaust systems
General Administration18%- Manufacturer's instructions and listings
- Permits and inspections
- Plan review and documentation
- Code authority and enforcement
Fuel Supply Systems10%- Gas appliances and connections
- Pressure regulation and overpressure protection
- Piping testing and inspection
- Fuel gas piping materials and installation
Heating, Cooling & Water Heaters18%- Solar thermal systems
- Heat pumps and cooling equipment
- HVAC equipment installation and clearance
- Water heaters and storage tanks
- Boilers and hydronic systems
Duct Systems12%- Duct construction and materials
- Insulation and sealing
- Duct installation and supports
- Dampers and access doors
Combustion Air8%- Confined spaces and equipment rooms
- Air supply and venting
- Combustion air requirements

>> International Code Council M2合格資料 <<

M2関連合格問題 & M2模擬問題

Jpexamの専門家チームは彼らの経験と知識を利用して長年の研究をわたって多くの人は待ちに待ったInternational Code CouncilのM2「Commercial Mechanical Inspector」認証試験について教育資料が完成してから、大変にお客様に歓迎されます。Jpexamの模擬試験は真実の試験問題はとても似ている専門家チームの勤労の結果としてとても値打ちがあります。

International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q26-Q31):

質問 # 26
What is the maximum distance allowed below the design flood elevation from which ventilation may be obtained?

正解:B

解説:
This question appears to contain a wording issue. In ICC flood-related provisions tied to ventilation/flood openings, the governing limit is that the opening location is not more than 1 foot relative to the reference grade condition used for flood-opening compliance. That corresponds to 1 foot , so Option C is the best- supported answer.


質問 # 27
Where the cooking surface has exposed flame and burners, the minimum distance between the lowest edge of a grease filter and the cooking or heating surface shall be _____ inches.

正解:B

解説:
For cooking equipment with exposed flame and burners , the IMC table for grease-filter mounting position requires a minimum vertical separation of 24 inches between the lowest edge of the grease filter and the cooking surface. That makes B correct.


質問 # 28
An 8-inch Type B venting system with a listed vent cap must terminate a minimum of _____ feet above the flat roof through which it passes.

正解:B

解説:
For a Type B gas vent with a listed vent cap terminating through a flat roof , the minimum required termination height is 1 foot above the roof . That makes Option A correct. This is consistent with gas vent termination tables used with listed Type B vent systems and the code framework for Type B vent terminations.


質問 # 29
When testing dampers located in corridors, the dampers shall demonstrate acceptable closure performance when subjected to _____ fpm velocity across the face of the damper using the UL 555 fire exposure test.

正解:D

解説:
Corridor damper testing under the referenced standard requires acceptable closure performance at 150 fpm across the face of the damper. Therefore Option C is correct.


質問 # 30
Indoor combustion air shall be provided within:

正解:D


質問 # 31
......

弊社のJpexamは専門的、高品質のInternational Code CouncilのM2問題集を提供するサイトです。International Code CouncilのM2問題集は専業化のチームが改革とともに、開発される最新版のことです。International Code CouncilのM2問題集には、詳細かつ理解しやい解説があります。このように、客様は我々のM2問題集を手に入れて勉強したら、試験に合格できるかのを心配することはありません。

M2関連合格問題: https://www.jpexam.com/M2_exam.html