At ExamPrepAway, we strive hard to offer a comprehensive Pure Storage Certified FlashArray Implementation Specialist (FlashArray-Implementation-Specialist) exam questions preparation material bundle pack. The product available at ExamPrepAway includes Pure Storage FlashArray-Implementation-Specialist Real Dumps pdf and mock tests (desktop and web-based). Practice exams give an experience of taking the Pure Storage Certified FlashArray Implementation Specialist (FlashArray-Implementation-Specialist) actual exam.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
>> Updated Pure Storage FlashArray-Implementation-Specialist Test Cram <<
The Pure Storage Certified FlashArray Implementation Specialist exam questions are very similar to actual Pure Storage Certified FlashArray Implementation Specialist FlashArray-Implementation-Specialist Exam Questions. So it creates a real FlashArray-Implementation-Specialist exam scenario for trustworthy users. As it is a Browser-Based Pure Storage Certified FlashArray Implementation Specialist FlashArray-Implementation-Specialist practice exam so there is no need for any installation. The Web-Based Pure Storage Certified FlashArray Implementation Specialist practice exam is supported by all major browsers like Chrome, IE, Firefox, Opera, and Safari. Furthermore, no special plugins are required to start your journey toward a bright career.
NEW QUESTION # 88
A dark site customer requests an evacuation of SH01 on a FlashArray/M50. What is an appropriate next step?
Answer: A
Explanation:
For a Dark Site customer (where Remote Assist and PhoneHome are disabled), the appropriate next step before performing a shelf evacuation is to use the evac_checks script.
Risk Mitigation: Evacuating a shelf is a resource-intensive operation that permanently removes physical capacity from the system. In a connected environment, Pure Support runs remote diagnostics to verify the array has enough free space and system resources to handle the evacuation safely.
Dark Site Procedure: Since Support cannot log in remotely, the Implementation Engineer must manually run the evac_checks python script (typically loaded via USB or available in the Purity toolkit). This script performs the equivalent validation: checking effectively used capacity, dedup ratios, and system load to predict if the remaining drives can absorb the data from Shelf 01 without filling the array to 100% or causing performance degradation. Relying solely on a generic percentage (Option B or C) is dangerous because it doesn't account for data reduction overhead or specific RAID overheads.
NEW QUESTION # 89
Which PCIe slot supports 4-port FC cards on FlashArray//XL?
Answer: B
Explanation:
On the FlashArray//XL , the 4-port Fibre Channel (FC) cards are specifically supported in Slot 8 (and typically Slot 4 depending on configuration depth). The FlashArray//XL chassis (5U) utilizes a significantly different PCIe bus layout compared to the standard 3U FlashArray//X series. While the //X series typically uses Slot 0 or Slot 2 for host connectivity, the //XL architecture reserves the lower-numbered slots (0-3) primarily for backend connectivity (SAS/NVMe-oF) or specific NVRAM modules in certain configurations.
To support the high bandwidth requirements of the 4-port 32Gb FC cards, the //XL chassis provides specific x16 electrical slots. Slot 8 is a designated high-performance slot located in the upper riser section of the controller, making it the correct placement for these dense host I/O cards. Using an incorrect slot such as Slot
2 (often x8 or reserved for other functions in XL) would likely result in the card not being recognized or operating at reduced performance. Therefore, Implementation Engineers must verify the specific "slot map" for the //XL model in the FlashArray//XL Hardware Guide before seating cards, with Slot 8 being the standard supported location for the 4-port FC option among the choices provided.
NEW QUESTION # 90
On a FlashArray//X50 R2/R3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?
Answer: C
Explanation:
For the FlashArray//X50 R2 and R3 models, the default Fibre Channel (FC) configuration utilizes a 4-port PCIe Fibre Channel card installed in Slot 0.
The hardware architecture of the FlashArray//X series differentiates slot usage based on the model controller chassis.
FlashArray//X10 and //X20: These lower-end models utilize Slot 2 for host connectivity (Fibre Channel or iSCSI) because Slots 0 and 1 are typically reserved or occupied by onboard controllers/mezzanine cards. The standard card for these models is often a 2-port card.
FlashArray//X50, //X70, and //X90: These mid-to-high-range models feature a different PCIe bus layout. Slot 0 is the primary designated slot for Host I/O connectivity. To support the higher performance capabilities and port density requirements of the X50, Pure Storage defaults to 4-port FC cards (typically 16Gb or 32Gb).
Therefore, identifying the model number is crucial. Since the question specifies the X50 (R2/R3), the correct placement is Slot 0, and the correct card type is the 4-port model. Option A is incorrect because the 2-port card is not the standard default for the performance-tier X50. Option B describes the configuration for an X20, not an X50.
NEW QUESTION # 91
Which NVRAM bays are always populated on the FlashArray//XR2/3?
Answer: C
Explanation:
On standard Pure Storage FlashArray models, including the //XR2 and //XR3 generations, the hardware architecture relies heavily on dedicated, non-volatile memory (NVRAM) modules. These modules are responsible for safely ingesting incoming host writes and protecting data in flight against unexpected power loss or controller failures before the data is ultimately destaged to the capacity flash drives.
To maintain absolute high availability and guarantee there is no single point of failure within the write cache, this NVRAM must always be mirrored across separate physical modules. During the physical hardware installation, the Implementation Engineer populates the dedicated NVRAM bays located centrally on the front bezel of the chassis. According to official Pure Storage implementation guidelines, the primary pair of NVRAM modules must always be installed in the first two designated bays, which are explicitly labeled 0 and 1 (NVB0 and NVB1).
While higher-performance arrays in the series (like the //X70 and //X90) possess enough ingest bandwidth to require populating bays 2 and 3 as well, bays 0 and 1 are the universal minimum baseline that is definitively populated across every array in the series to ensure N+1 cache redundancy.
NEW QUESTION # 92
What is the rack unit height of a FlashArray//XL?
Answer: B
Explanation:
The FlashArray//XL features a 5 Rack Unit (5U) chassis height.
This form factor represents a significant change from the standard FlashArray//X and //C series, which utilize a 3U chassis. The increase to 5U is engineered to support the massive performance and density requirements of the //XL platform.
Key Design Features: The 5U height accommodates:
Dual Controllers: Larger, high-performance controllers with increased airflow requirements.
40 DirectFlash Module Slots: Double the drive density of the 3U chassis (which holds 20), allowing for petabytes of effective capacity in the base unit.
4 Power Supplies: A 2+2 redundant power architecture.
9 PCIe Slots: Extensive I/O expansion for host and backend connectivity.
Airflow: Dedicated fan modules and thermal ducting to cool the high-wattage components (up to 3.5kW max power draw).
NEW QUESTION # 93
......
Not withstanding zeroing in on our material, expecting that you went after in the Pure Storage FlashArray-Implementation-Specialist exam, you can guarantee your cash back as per systems. By seeing your goofs you can work on your show continually for the FlashArray-Implementation-Specialist Exam approach. You can give vast phony tests to make them ideal for Pure Storage Certified FlashArray Implementation Specialist (FlashArray-Implementation-Specialist) exam and can check their past given exams. Pure Storage FlashArray-Implementation-Specialist Dumps will give reliable free updates to our clients generally all the Pure Storage FlashArray-Implementation-Specialist certifications.
FlashArray-Implementation-Specialist Learning Materials: https://www.examprepaway.com/Pure-Storage/braindumps.FlashArray-Implementation-Specialist.ete.file.html