The VNX301 dumps of DumpStillValid include valid Versa Certified SD-WAN Specialist (VNX300) (VNX301) questions PDF and customizable VNX301 practice tests. Our 24/7 customer support provides assistance to help VNX301 Dumps users solve their technical hitches during their test preparation. The VNX301 exam questions of DumpStillValid come with up to 365 days of free updates and a free demo.
| Certification Vendor: | Versa Networks |
|---|---|
| Exam Name: | Versa Certified SD-WAN Specialist |
| Exam Number: | VNX301 |
| Related Certifications: | Versa Certified SD-WAN Expert |
| Passing Score: | 70% |
| Exam Duration: | 90 minutes |
| Available Languages: | English |
| Real Exam Qty: | 60 |
| Exam Price: | USD 250 |
| Exam Format: | Multiple Select, Multiple Choice |
| Certificate Validity Period: | 3 years |
| Sample Questions: | Versa Networks VNX301 Sample Questions |
| Exam Way: | Online proctored exam at Pearson VUE test centers |
| Pre Condition: | Recommended: Basic networking knowledge (CCNA/equivalent), familiarity with WAN technologies and enterprise network design |
| Official Syllabus URL: | https://www.versa-networks.com/partners/training-certification.html |
>> Prep Versa Networks VNX301 Guide <<
Several advantages we now offer for your reference. On the one hand, our VNX301 learning questions engage our working staff in understanding customers’ diverse and evolving expectations and incorporate that understanding into our strategies, thus you can 100% trust our VNX301 Exam Engine. On the other hand, the professional VNX301 study materials determine the high pass rate. According to the research statistics, we can confidently tell that 99% candidates have passed the VNX301 exam.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
NEW QUESTION # 32
A business-critical application should remain on the best SLA-compliant circuit. When all SLA-compliant circuits fail, the traffic must be dropped instead of being forwarded on a degraded path. Which forwarding- profile setting should be changed?
Answer: D
Explanation:
The correct answer is A . In Versa SD-WAN traffic steering, forwarding profiles define how traffic is mapped to WAN circuits, how next hops are selected, and how traffic behaves when SLA conditions are violated. If the requirement is to stop traffic when no SLA-compliant path is available, the relevant behavior is the SLA Violation Action . Setting this option to Drop prevents the VOS device from forwarding the matching traffic over a circuit that does not satisfy the policy's SLA requirements.
This is the opposite of using Forward , which allows traffic to continue even when the available next hops violate the SLA. Forward may be appropriate for best-effort applications where degraded delivery is better than no delivery, but it is not appropriate for strict business-critical applications that must not use a degraded path.
Nexthop Failure Action controls how the system behaves when a next hop fails, such as waiting for recovery or re-evaluating. Header compression affects packet overhead, and the recompute timer controls periodic recalculation timing. None of those settings directly enforce "drop when SLA is not met."
NEW QUESTION # 33
Which two statements are true about templates? (Choose two.)
Answer: B,C
Explanation:
The correct answers are C and D . Versa templates are designed to reuse common configuration while still allowing per-device customization. Template variables allow the same template to be deployed to multiple appliances while using device-specific values such as addresses, VLAN IDs, DHCP information, or other bind-data values. Versa documentation for deploying templates describes assigning values to variables contained in a main template that are specific to the device. This makes option C correct.
Option D is also correct because Versa workflows are used to create templates for VOS device configuration.
Versa documentation states that workflows are used to create templates to configure VOS devices, and also to create templates for application steering, spoke groups, and service chains.
Option A is not correct in the normal Versa Director onboarding model because a group of devices is associated with one staging template and one post-staging template, rather than multiple device templates being stacked per appliance. Option B is also incorrect because service templates are optional reusable service-specific fragments. Versa documentation states that service templates can be used by multiple device templates and device groups, but it does not require every appliance to have one.
NEW QUESTION # 34
Examine the exhibit below.
As an administrator of a Versa Secure SD-WAN, you are asked to find the current bandwidth of each WAN circuit used for SD-WAN connectivity in a branch, but the Director is not displaying any information for the WAN circuits.
In this scenario, what should be done to get the graph populated for all WAN circuits?
Answer: B
Explanation:
The correct answer is B . The exhibit shows the branch interface summary in Versa Director with a Live Data column. To populate real-time bandwidth graphs for WAN circuits, the administrator must select Live Data for the WAN interfaces that need to be monitored. Versa monitoring documentation states that, from a Director node, you can monitor VOS devices and organizations, and that Director, together with Versa Analytics, can poll VOS devices in real time to understand what is happening on the devices. This real-time information can be displayed to assist with troubleshooting.
Because the question asks for the current bandwidth of each WAN circuit, historical analytics alone is not sufficient. The dashboard must poll live statistics from the selected WAN circuits. In the exhibit, not all WAN interfaces appear to have Live Data selected; therefore, the graph is not populated for all circuits. Refreshing the page does not enable polling and will not solve the missing data condition.
Selecting only MPLS would populate only the MPLS circuit, not all WAN circuits. Unselecting and reselecting only the INET circuit would affect only that one interface. Therefore, Live Data must be selected for all WAN circuits whose current bandwidth should be displayed.
NEW QUESTION # 35
A branch has correct underlay speed and no asymmetric SD-WAN paths, but users still report packet loss during large transfers. You suspect QoS shaping is dropping traffic. Which command is most appropriate to verify interface-level CoS drops?
Answer: B
Explanation:
The correct answer is A . Versa throughput troubleshooting documentation includes a specific section titled Check that Packets Are not Dropped by CoS . It states that if a CoS shaper or rate limiter is configured on the VOS device, it may drop packets when traffic exceeds the configured shaping rate. To check whether CoS is dropping packets, Versa recommends commands including show class-of-services interfaces brief and show class-of-services interfaces detail interface-name.
The detailed interface output displays traffic statistics such as TX packets, TX packets dropped, TX bytes, TX bytes dropped, and per-traffic-class drops. This is exactly the evidence needed to confirm whether shaping or QoS enforcement is causing the observed loss.
show alarms last-n 10 may reveal major events but will not provide per-interface CoS drop counters.
show system uptime only indicates how long the system has been running. show cgnat tenants is relevant for NAT state and tenant CGNAT resources, not QoS drops.
NEW QUESTION # 36
A customer is running VOS Release 22.1.3 on both the speed-test client and server. Which sequence is used by the Versa speed test to calculate bandwidth?
Answer: D
Explanation:
The correct answer is C . Versa documentation states that for Releases 22.1.3 and later , the speed test factors in network latency to derive results. In these releases, the speed test is performed in three stages : a ping test, an upload test, and a download test. The ping test calculates link latency, and the speed test uses that latency data while performing the upload and download portions.
The same documentation notes that the speed test can measure bandwidth speeds up to 1 Gbps, with actual measurement depending on factors such as in-path shapers and latency. It also states that the test may use up to 45 MB of data per upload or download in the best case and 90 MB for a complete test.
Older releases behave differently. For Releases 21.2 and earlier, the speed test is performed in two stages: upload and download. Therefore, because the question specifically states Release 22.1.3 on both client and server, the correct sequence is ping, upload, and download.
NEW QUESTION # 37
......
Study VNX301 Reference: https://www.dumpstillvalid.com/VNX301-prep4sure-review.html