| Section | Objectives |
|---|---|
| Fire-Resistance & Protection | - Concealed Spaces Protection - Fire-Resistance-Rated Assemblies - Noncombustible Protection & Encapsulation |
| Mass Timber Materials | - CLT, Glulam, NLT, SCL and Engineered Wood Products |
| Inspection Duties & Documentation | - Statement of Special Inspections - Inspection Reporting and Compliance Verification |
| Structural & Connection Inspection | - Framing and Structural Elements - Connection Design and Protection |
| General & Construction Types | - Construction Classification — Type IV-A, IV-B, IV-C
|
| Construction Fire Safety |
>> International Code Council 93-Tall-Mass-Timber-Buildings證照 <<
當你感到悲哀痛苦時,最好是去學些什麼東西,比如通過93-Tall-Mass-Timber-Buildings考試,獲得該證書可以使你永遠立於不敗之地。我們的IT團隊致力于提供真實的International Code Council 93-Tall-Mass-Timber-Buildings題庫問題和答案,所有購買我們93-Tall-Mass-Timber-Buildings題庫的客戶都將獲得長達一年的免費更新,確保考生有足夠的時間學習。成功不是將來才有的,而是從決定去做的那一刻起,持續累積,International Code Council 93-Tall-Mass-Timber-Buildings考古題學習資料是根據最新的考試知識點整編而來,覆蓋面廣,是你備考的最佳助手。
問題 #39
One code-recognized method for calculating the fire-resistance rating of exposed wood members and decking is:
答案:B
解題說明:
The intended answer is ANSI/AWC NDS Chapter 16. The video option uses "AWS," but the correct standards organization is the American Wood Council-AWC . Option D is therefore correct based on its intended reference.
IBC Section 722.1 expressly permits exposed wood members and wood decking to have their calculated fire resistance determined in accordance with Chapter 16 of the ANSI/AWC National Design Specification for Wood Construction. The method evaluates charring, the effective char depth, the reduced residual cross section, elevated-temperature effects, loading, and the remaining structural capacity for the required exposure period.
ACI 216.1 applies to concrete and masonry fire resistance. TMS 0216 addresses masonry assemblies. ASCE
29 Chapter 5 provides procedures for calculating the fire resistance of structural steel assemblies. Those references are code-recognized methods, but they apply to different construction materials.
For mass timber inspection, the approved calculations should identify the exposed surfaces, required rating, timber species or product, member dimensions, design loads, protective contribution, and connection treatment. Field reductions in member dimensions can invalidate the calculated fire resistance.
References/Topics: 2021 IBC Section 722.1; ANSI/AWC NDS Chapter 16; calculated fire resistance of exposed wood members and decking.
問題 #40
Which of the following is true regarding Type IV-B unprotected portions of mass timber ceilings and walls?
答案:D
解題說明:
Type IV-B construction is fundamentally protected mass timber construction, but the 2021 IBC permits specifically limited areas of interior mass timber to remain exposed. Section 602.4.2.2.2 establishes two independent exposure limits. Unprotected portions of mass timber ceilings, including attached beams, are limited to 20 percent of the floor area of the dwelling unit or fire area. Unprotected portions of mass timber walls, including attached columns, are limited to 40 percent of that floor area . Accordingly, option C correctly states the permitted percentages.
These percentages do not operate in isolation. Exposed areas must also comply with Section 602.4.2.2.4, which establishes separation requirements between unprotected mass timber surfaces. Where both walls and ceilings are exposed within the same dwelling unit or fire area, Section 602.4.2.2.3 requires use of the mixed- unprotected-area equation rather than independently maximizing both percentages.
Option A describes neither Type IV-B nor its controlled-exposure concept. Option B incorrectly characterizes Type IV-B as requiring complete encapsulation. Option D reverses the ceiling and wall percentages.
References/Topics: 2021 IBC Sections 602.4.2.2.2, 602.4.2.2.3 and 602.4.2.2.4; Type IV-B permitted exposed mass timber.
問題 #41
Refer to the figure by clicking on the EXHIBIT button above.

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?
答案:B
解題說明:
The figure depicts an unprotected portion of the mass timber ceiling . For Type IV-B construction, Section
602.4.2.2.2, Exception 1.1, limits unprotected ceiling areas-including attached mass timber beams-to 20 percent of the floor area of the applicable dwelling unit or fire area. Option B is therefore correct.
The percentage is based on floor area rather than total ceiling surface area. For example, where the associated fire area contains 1,000 square feet of floor area, the maximum ceiling exposure permitted under this particular exception would be 200 square feet, subject to the additional separation and mixed-exposure provisions.
The 40-percent value in option D applies to mass timber walls, including attached columns , rather than ceilings. The 15-percent and 30-percent values are not the prescribed Type IV-B ceiling exposure limitations in the 2021 IBC.
The inspector must additionally determine whether another exposed wall or ceiling region exists nearby.
Section 602.4.2.2.4 imposes a 15-foot separation requirement, and Section 602.4.2.2.3 controls situations where both wall and ceiling surfaces are intentionally exposed.
References/Topics: 2021 IBC Sections 602.4.2.2.2 through 602.4.2.2.4; Type IV-B ceiling exposure limitations.
問題 #42
Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?
答案:C
解題說明:
Option A correctly reflects the required noncombustible protection for protected Type IV-A mass timber.
Under IBC Section 602.4.1.2.1, the noncombustible protection applied to interior faces of Type IV-A mass timber must contribute the protection time determined by the applicable provisions of Section 722.7, but not less than 80 minutes .
The broader Type IV provisions are particularly important for interior exit and elevator hoistway enclosures.
In qualifying tall mass timber buildings with an occupied floor more than 75 feet above the lowest level of fire department access, mass timber interior exit and elevator hoistway enclosures are permitted up to the specified height limits only where protected in accordance with Section 602.4.1.2. For a two-hour, 120- minute-rated enclosure, at least 80 minutes must therefore come from the prescribed noncombustible protection.
Type IV-B likewise uses an 80-minute minimum for protected interior mass timber, so option B ' s 40-minute value is incorrect. Type IV-C has different exposure allowances and shaft-protection provisions, but option C does not state the controlling tall-building enclosure requirement tested here. Type IV-HT is not governed by the Type IV-A tall mass timber enclosure protection rule.
References/Topics: 2021 IBC Sections 602.4 and 602.4.1.2 through 602.4.1.2.1; Section 722.7.
問題 #43
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
答案:A
解題說明:
A 7/16-inch wood structural panel is not one of the prescriptively acceptable fireblocking materials listed by IBC Section 718.2.1. Therefore, option C is correct.
Section 718.2.1 permits fireblocking to consist of several specified materials. These include one-half-inch gypsum board; properly secured batts or blankets of mineral wool, mineral fiber, or other approved materials; and mass timber complying with Section 2304.11. Options A, B, and D are consequently valid.
For wood structural panels, however, the IBC requires a substantially greater thickness: a single thickness of approximately 0.719 inch , conventionally represented as 23/32 inch, with joints backed by material of the same required thickness. A 7/16-inch panel is only approximately 0.438 inch thick and therefore does not satisfy that prescriptive fireblocking provision.
Fireblocking is intended to interrupt concealed draft openings and restrict the movement of flame and hot gases through concealed combustible spaces. It should not be confused with a tested firestop system used at penetrations through fire-resistance-rated assemblies.
Special inspection should confirm that the installed material, thickness, joint backing, retention, and location conform to the approved construction documents and the applicable code provision.
References/Topics: 2021 IBC Sections 718.2 and 718.2.1; Section 2304.11; permitted fireblocking materials.