International Code CouncilのM2認定試験に受かるためにがんばって勉強していれば、Jpexamはあなたにヘルプを与えます。Jpexam が提供したInternational Code CouncilのM2問題集は実践の検査に合格したもので、最も良い品質であなたがInternational Code CouncilのM2認定試験に合格することを保証します。

International Code Council M2 Exam Syllabus Topics:

SectionWeightObjectives
Duct Systems12%- Duct construction and materials
- Dampers and access doors
- Insulation and sealing
- Duct installation and supports
Exhaust & Ventilation Systems20%- Hazardous and special exhaust systems
- Ventilation rates and outdoor air requirements
- Commercial kitchen exhaust systems
- Makeup air systems
Fuel Supply Systems10%- Pressure regulation and overpressure protection
- Gas appliances and connections
- Piping testing and inspection
- Fuel gas piping materials and installation
Chimneys & Vents14%- Vent systems and connections
- Chimney construction and materials
- Clearances and termination requirements
- Factory-built chimneys and vents
Heating, Cooling & Water Heaters18%- Boilers and hydronic systems
- Heat pumps and cooling equipment
- Solar thermal systems
- HVAC equipment installation and clearance
- Water heaters and storage tanks
Combustion Air8%- Combustion air requirements
- Air supply and venting
- Confined spaces and equipment rooms
General Administration18%- Permits and inspections
- Manufacturer's instructions and listings
- Code authority and enforcement
- Plan review and documentation

>> M2復習テキスト <<

International Code Council M2日本語受験教科書 & M2模擬対策問題

Jpexamは長年にわたってずっとIT認定試験に関連するM2参考書を提供しています。これは受験生の皆さんに検証されたウェブサイトで、一番優秀な試験M2問題集を提供することができます。Jpexamは全面的に受験生の利益を保証します。皆さんからいろいろな好評をもらいました。しかも、Jpexamは当面の市場で皆さんが一番信頼できるサイトです。

International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q28-Q33):

質問 # 28
Exhibit:

CEF-5 is a ceiling exhaust fan manufactured by:

正解:A

解説:
This is also an exhibit-reading question. From the equipment schedule in the image, CEF-5 is listed as a Nutone unit, so Option D is correct. This falls under reading commercial mechanical drawings and equipment schedules related to exhaust/ventilation components.


質問 # 29
The exhibit shows a _____ in. diameter gas line between unit heaters 5 and 8.

正解:A

解説:
Based on the mechanical plan shown in the exhibit, the gas line between unit heaters 5 and 8 is labeled as 1 inch in diameter. Therefore, the correct answer is B.


質問 # 30
The minimum size for access openings for fire dampers shall be:

正解:A

解説:
The IMC requires access openings for fire dampers to be of a size that allows maintenance and resetting of the damper . The code does not set the answer as same-as-duct, half-diagonal, or a universal 12-inch by 12- inch opening. So Option C is correct.


質問 # 31
An equipment shutoff valve shall be in the same room and not more than how many feet away from the appliance?

正解:B

解説:
The IFGC requires the appliance shutoff valve to be located in the same room as the appliance and within
6 feet of the appliance . Therefore, the correct answer is A .


質問 # 32
The exhaust outlet for a clothes dryer is required to be equipped with:

正解:A

解説:
The IMC requires clothes dryer exhaust ducts to terminate outside the building and to be equipped with a backdraft damper at the terminal. The code also prohibits screens at dryer terminations because lint can accumulate and obstruct flow. That makes Option A correct and eliminates Option C . The other two choices describe controls not required by the dryer exhaust termination rule.


質問 # 33
......