As we all know, through the judicial examination, you need to become a lawyer, when the teacher is need through the teachers' qualification examinations. If you want to be an excellent elites in this line, you need to get the HCSP-Field-Data Center Facility V1.0 certification, thus it can be seen through the importance of qualification examination. Only through qualification examination, has obtained the corresponding qualification certificate, we will be able to engage in related work, so the H20-923_V1.0 Test Torrent is to help people in a relatively short period of time a great important tool to pass the qualification test.

Huawei H20-923_V1.0 Exam Overview:

Certification Vendor:Huawei
Exam Name:HCSP-Field-Data Center Facility V1.0
Exam Number:H20-923_V1.0
Exam Price:USD 300
Certificate Validity Period:3 Years
Passing Score:600/1000
Exam Duration:90 minutes
Related Certifications:Huawei Certified Solution Specialist (HCSP)
Real Exam Qty:60
Available Languages:English, Chinese
Exam Format:Multiple-answer, Drag-and-drop, True/False, Single-answer
Sample Questions:Huawei H20-923_V1.0 Sample Questions
Exam Way:Pearson VUE
Pre Condition:None
Official Syllabus URL:https://e.huawei.com/en/talent/exam/#/cert/6000000000000000020

>> H20-923_V1.0 New Real Test <<

Valid H20-923_V1.0 Exam Topics, H20-923_V1.0 Exam Collection

Our Huawei H20-923_V1.0 dumps assists the candidates of the test with its three formats to advance their preparation as per various learning needs. A team of experts at ActualPDF has designed the H20-923_V1.0 Pdf Format to help applicants who are too busy to prepare intensively for the Huawei H20-923_V1.0 certification exam on the first go.

Huawei H20-923_V1.0 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Huawei FusionCol8000-A Lab Guide: This is a heavily weighted practical lab section focused on the hands-on deployment, configuration, commissioning, and maintenance of the FusionCol8000-A cooling system in a field-representative setting.
Topic 2
  • Basic Knowledge of Power Distribution: This topic covers the fundamental concepts of power distribution within a data center, including electrical principles, distribution topologies, and key components such as switchgear and PDUs.
Topic 3
  • Huawei Other DCIM Tools: This topic explores additional Huawei Data Center Infrastructure Management tools beyond the ECC800-Pro and NetEco 6000, covering their functions and how they complement the overall DCIM ecosystem.
Topic 4
  • Huawei DCIM Installation and Deployment Lab Guide: This topic is a guided hands-on section covering the step-by-step installation and initial deployment procedures for Huawei DCIM systems in a lab environment.
Topic 5
  • FusionCol8000-C (110-440) In-Room Chilled Water Smart Cooling Product: This topic covers the FusionCol8000-C chilled water in-room cooling unit, including its product design, chilled water system integration, smart control features, and deployment scenarios.
Topic 6
  • Introduction to the Modular Data Center FusionModule2000: This topic introduces the FusionModule2000 modular data center, covering its design concepts, components, and the scenarios in which it is deployed.
Topic 7
  • Huawei UPS5000H Lab Guide: This is a heavily weighted hands-on lab section covering practical installation, commissioning, parameter configuration, and maintenance operations for the UPS5000H in a field-simulated environment.
Topic 8
  • Data Center Cooling Solutions: This topic provides an overview of cooling technologies and strategies used in data centers, including air-side and water-side cooling architectures and Huawei's approach to thermal management.
Topic 9
  • FusionCol8000-A230 In-Room Air Cooled (Air-Cooled Fan Wall) Smart Cooling Product: This topic addresses the FusionCol8000-A230 air-cooled fan wall solution, covering its working principles, product specifications, installation considerations, and smart cooling management capabilities.
Topic 10
  • SmartLi 3.0 (Short-Term Backup Power) Installation: This topic covers the installation procedures for the SmartLi 3.0 system, including hardware setup, cabling requirements, and commissioning steps.
Topic 11
  • Training on FusionDC1000A: This topic focuses on the FusionDC1000A prefabricated data center solution, covering its product features, deployment methods, and operational maintenance requirements.
Topic 12
  • Huawei DCIM Lab Guide: This topic is a broader practical lab section covering operational tasks, configuration, and troubleshooting exercises across Huawei DCIM platforms to build field-level proficiency.
Topic 13
  • UPS Basic Knowledge: This topic introduces the foundational concepts of Uninterruptible Power Supply systems, including operating modes, topology types, and their role in ensuring power continuity for data center loads.

Huawei HCSP-Field-Data Center Facility V1.0 Sample Questions (Q71-Q76):

NEW QUESTION # 71
The UPS5000-H-1200 kVA and UPS5000-H-1600 kVA have two power cabinets and one bypass cabinet, and are equipped with the MDU, ECU, and surge protection box.

Answer: A

Explanation:
This statement is incorrect because it combines two different frame configurations into one description. In the UPS5000-H family, cabinet composition depends on capacity. For the UPS5000-H-1200 kVA, the user manual's exterior description shows a single power cabinet plus a bypass cabinet, together with the MDU. In other words, 1200 kVA is not described as "two power cabinets + one bypass cabinet" in its standard cabinet topology. By contrast, the UPS5000-H-1600 kVA is a wider frame and its maintenance/structure description explicitly shows Power cabinet 1, Power cabinet 2, and a bypass cabinet, and the product documentation also includes component sections for items like the surge protection box and MDU. Because the 1200 kVA model does not match the "two power cabinets" description, the combined statement (covering both 1200 kVA and 1600 kVA) is false, even though the "two power cabinets + one bypass cabinet" part is valid for 1600 kVA.


NEW QUESTION # 72
The NetEco service program backend can be accessed through the iBMC port.

Answer: A

Explanation:
In Huawei data center facility management, NetEco is the management software platform (server/application) used to centrally monitor and manage sites, while iBMC is the out-of-band hardware management interface used for server remote maintenance (such as power control, hardware health, BIOS settings, and remote console) on the specific server where iBMC exists.
The iBMC port is not a service access interface for NetEco. NetEco's backend services are accessed through the server operating system network interfaces (management/service network) and corresponding application ports after the server is properly networked and configured. Even if NetEco is deployed on a Huawei server that has iBMC, iBMC only provides a channel to manage the server hardware and does not expose NetEco application access as an official commissioning/O&M path. Therefore, NetEco backend access should be planned via the site's management network (IP addressing, routing, security policy), not via iBMC.


NEW QUESTION # 73
During routine maintenance of the lithium battery cabinet, which of the following procedure is true about replacing a faulty battery module?

Answer: A

Explanation:
The correct sequence prioritizeselectrical safety first, then mechanical disassembly. You mustconfirm the batteries are not discharging(Step 1) to avoid working under load. Next, the cabinet must be placed into a safe powered-down state byswitching off the battery circuit breaker and long-pressing the POWER ON/OFF button to power off the cabinet(Step 6). Only after the cabinet is safely powered down should you open up the working area byremoving the front covers of the faulty module and adjacent modules(Step 3). Then youturn off the ready switchon the battery management module (Step 2) to prevent the system from re-enabling the module unexpectedly during maintenance. After that, youloosen the securing bolts and pull out the battery management module about 10 cm(Step 5) to create operating space and ensure isolation for subsequent operations. With the cabinet safely stopped, you canremove the cables and copper barsconnected to the faulty module (Step 7), and finallyremove the baffle plate and pull out the faulty battery module(Step 4).


NEW QUESTION # 74
The NetEco northbound interface does not support the SNMP protocol. Only WebService interfaces are supported.

Answer: A

Explanation:
In Huawei's data center facility management architecture, thenorthbound interfaceof NetEco is designed specifically to integrate with upper-layer systems such as enterprise NMS platforms, SOC/monitoring centers, and customer unified O&M systems. To meet common industry integration practices, NetEco northbound capabilities are not limited to only one interface type. In addition to WebService-style interfaces used for richer data exchange and structured integration, NetEco also supportsSNMP-based northbound integration, which is widely used for alarm forwarding, basic status monitoring, and interoperability with standard network management tools. SNMP is particularly common in mixed-vendor environments because it enables a lightweight and standardized method to deliver key alarms and events to a customer's central monitoring platform without requiring deep application coupling. Therefore, the statement that "only WebService interfaces are supported and SNMP is not supported" is incorrect: NetEco northbound integration supports SNMP along with other northbound interface methods depending on the integration scenario and customer requirements.


NEW QUESTION # 75
When the outdoor unit is installed at a position higher than the indoor unit, install an oil trap every five to six meters in the vertical direction along the gas pipe to ensure system reliability.

Answer: A

Explanation:
This statement is true. In split DX/precision cooling refrigerant systems, the "gas pipe" typically refers to the suction line returning refrigerant vapor (and entrained compressor oil) from the indoor evaporator to the outdoor unit/compressor. When the outdoor unit is higher than the indoor unit, the suction line includes a vertical riser. Oil naturally tends to settle and flow downward under gravity, so without proper piping measures, oil may accumulate in low points or fail to be carried upward consistently, leading to poor oil return. Insufficient oil return can cause compressor lubrication issues, abnormal noise, overheating, reduced efficiency, and long-term reliability risks. Installing oil traps at the bottom of the riser and then every 5? meters of vertical lift helps collect oil and allows it to be periodically swept upward by refrigerant velocity, maintaining stable oil circulation. This requirement is especially important in data center cooling because continuous operation and high availability demand reliable compressor lubrication and stable refrigerant flow under varying load conditions.


NEW QUESTION # 76
......