| Section | Objectives |
|---|---|
| Fire Protection and Fire-Resistance | - Fire-resistance requirements - Noncombustible protection and protection of mass timber elements - Fire protection systems and related provisions |
| Code Compliance and Related Requirements | - Energy code requirements applicable to mass timber buildings - Documentation and verification of compliance - Sound transmission requirements |
| Special Inspection Requirements | - Special inspection procedures for tall mass timber buildings - Inspection of connections and protective materials - Inspector duties and responsibilities |
| Tall Mass Timber Building Code Provisions | - Mass timber materials and construction requirements - Types IV-A, IV-B and IV-C construction - International Building Code requirements for tall mass timber construction |
| Structural Inspection | - Structural loads and related code requirements - Mass timber structural elements - Connections and fastening systems |
| Construction Fire Safety | - Protection of mass timber during construction - Construction-phase fire safety requirements - International Fire Code requirements |
>> 93-Tall-Mass-Timber-Buildings復習範囲 <<
93-Tall-Mass-Timber-Buildings練習教材を購入したすべての学生は、International Code Councilの93-Tall-Mass-Timber-Buildings学習教材が提供する内容に従い、毎日学習する限り、プロの93-Tall-Mass-Timber-Buildings資格試験に合格できると信じています。 模擬試験を通じて定期的に自己検査を実施します。 もちろん、Tech4Exam購入する前に、93-Tall-Mass-Timber-Buildings学習教材は無料の試用サービスを提供します。当社のWebサイトにログオンしている限り、無料で試用版の93-Tall-Mass-Timber-Buildings質問バンクをダウンロードできます。 93-Tall-Mass-Timber-Buildingsテストエンジンを試した後、あなたはそれらを愛することになると信じています。
質問 # 44
Refer to the figure by clicking on the EXHIBIT button above.

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure are required to be separated by _____ feet.
正解:C
解説:
The required separation is 15 feet , making option B correct. Section 602.4.2.2.4 of the 2021 IBC specifically regulates the separation distance between unprotected mass timber elements in Type IV-B construction.
Within each dwelling unit or fire area, unprotected portions of mass timber walls and ceilings must be separated from other unprotected wall and ceiling portions by not less than 15 feet . For ceiling-related surfaces, the separation is measured horizontally along the ceiling. For wall-to-wall exposure, the applicable separation is measured horizontally along the floor.
This requirement operates in addition to the maximum exposed-area restrictions. A designer therefore cannot merely demonstrate that the exposed ceiling is below 20 percent or that exposed walls are below 40 percent of floor area; the exposed regions must also satisfy the required spatial separation.
The purpose is to prevent multiple exposed mass timber regions from acting as closely spaced fuel packages during a compartment fire. During inspection, dimensions should be checked against the approved documents before required gypsum or other noncombustible protection is completed.
References/Topics: 2021 IBC Section 602.4.2.2.4; separation distance between unprotected Type IV-B mass timber elements.
質問 # 45
Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?
正解:C
解説:
Option A is an exact requirement of the 2021 International Fire Code Section 3303.5 . For Type IV-A, IV- B, and IV-C buildings designed to exceed six stories above grade plane, standpipes must be provided in accordance with IFC Section 3313, unless otherwise approved by the fire code official.
The IFC also requires a water supply for fire department operations, but that supply must be approved by the fire code official and fire chief; the code does not specifically mandate that it be a "portable" water supply.
Option B is therefore incorrect.
The remaining options alter important numerical requirements. Where noncombustible protection is required and construction exceeds six stories, at least one layer , not two, must be installed on applicable building elements more than four levels below active mass timber construction before additional floor levels are erected. Required exterior wall coverings are likewise required more than four levels below active mass timber construction, rather than two.
These safeguards reduce the amount of exposed combustible construction while ensuring that effective fire department infrastructure progresses with the building.
References/Topics: 2021 IFC Section 3303.5; Sections 3313 and related construction-stage fire protection requirements.
質問 # 46
Sealants used to resist passage of air in construction Type IV-A, shall be in accordance with which of the following standards?
正解:B
解説:
ASTM C920 is the required standard for sealants used under the IBC mass timber air-sealing provision.
Option C is therefore correct. Section 703.7 applies to Type IV-A construction and requires compliant sealant or adhesive at specified interfaces involving fire-resistance-rated mass timber elements.
The sealing requirement reduces the movement of air, heat, and combustion gases into gaps that could expose additional timber surfaces and undermine the rated performance assumed by the approved design. The sealant must not merely appear to close the opening; it must be the specified product and installed within its approved joint dimensions and substrate conditions.
ASTM A36 is a structural steel material specification. ASTM E119 establishes procedures for fire testing building construction and assemblies but does not qualify elastomeric sealant products. ASTM F1667 covers driven fasteners such as nails, spikes, and staples and has no application to this sealing requirement.
Under Section 1705.20, installation is subject to periodic special inspection where the Section 703.7 sealant is applied. Inspection should occur before concealment and confirm continuity, adhesion, backing, joint depth, surface cleanliness, and compliance with the approved documents.
References/Topics: 2021 IBC Sections 703.7 and 1705.20; Type IV-A construction; ASTM C920.
質問 # 47
The maximum allowable height for a Group I-4 building of Type IV-B construction provided with an automatic sprinkler system in accordance with Section 903.3.1.1 is _____ ft.
正解:A
解説:
The applicable requirement is found in 2021 IBC Section 504.3 and Table 504.3. The table regulates building height in feet above grade plane by occupancy, construction type, and sprinkler condition. For a Group I-4 occupancy equipped throughout with a Section 903.3.1.1 sprinkler system, the applicable row is the sprinklered "S" row.
Reading across that row to Type IV-B construction gives a maximum building height of 120 feet. Therefore, option B is correct. The 180-foot value applies to Type IV-A construction for the same occupancy and sprinkler condition. The 85-foot value, which is not offered, applies to Type IV-C and Type IV-HT. The 270- foot value generally appears for certain lower-hazard occupancies-such as Groups A, B, E, F, M, S and U- when constructed as sprinklered Type IV-A, but it is not permitted for Group I-4.
This distinction reflects the additional life-safety considerations associated with custodial-care occupancies. A special inspector should verify that the approved construction documents identify both the correct occupancy classification and construction type because either classification directly changes the permitted height.
References/Topics: 2021 IBC Section 504.3; Table 504.3, Group I-4, sprinklered Type IV-B construction; Section 903.3.1.1.
質問 # 48
Concealed spaces in a Type IV-C building must be protected with:
正解:C
解説:
In Type IV-C construction, combustible construction forming concealed spaces must receive noncombustible protection providing an assigned time of at least 40 minutes. Consequently, option D is correct.
Type IV-C permits substantial portions of mass timber to remain exposed within occupied interior spaces, subject to the applicable construction and fire-resistance requirements. That permission does not extend unchanged into concealed spaces. Concealed combustible surfaces create a different hazard because fire can spread above ceilings, inside shafts, or within service cavities without immediate detection. Section 602.4.3.5 therefore imposes a specific 40-minute noncombustible protection requirement.
An NFPA 13 sprinkler system is generally required for tall mass timber buildings, but sprinkler protection alone is not the prescribed substitute for this concealed-space protection. Fire-retardant-treated wood is still combustible and does not constitute the required noncombustible protective membrane. Option C is also incorrect because the concealed-space rule is more specific than the provisions governing exposed surfaces in occupied spaces.
Inspection should occur before closure so that membrane continuity, board orientation, fastener spacing, joint treatment, penetrations, and protection around connection hardware can be fully observed.
References/Topics: 2021 IBC Sections 602.4.3.2 and 602.4.3.5; Table 722.7.1(1); concealed combustible construction in Type IV-C buildings.