| Section | Weight | Objectives |
|---|---|---|
| Introduction to Data Center Facility Partner Policies (Outside China) | 20% | - Cooperation process and authorization rules - Incentive and support policies - Partner classification and qualification requirements |
| Partner Quality Management | 10% | - Project delivery and acceptance requirements - Quality management system and standards - After-sales service and guarantee specifications |
| Introduction to Huawei Data Center Facility and Critical Power Solutions | 60% | - Overview of data center facility industry and development trends - Huawei data center facility product portfolio and positioning - Critical power system architecture and key technologies - Application scenarios and solution matching |
| Safety Management | 10% | - Safety standards and specifications for data center facilities - Risk identification and control measures - Safety requirements in design, construction and operation |
>> Huawei H19-105_V2.0学習体験談 <<
お客様の時間が大切だということが了解します。私たちのH19-105_V2.0試験問題集の一つの特徴は時間を節約できることです。お客様は支払いに成功した後、自分のメールアドレスで直接にH19-105_V2.0試験問題集をダウンロードできます。勉強するとき、H19-105_V2.0試験問題集の問題の答えを覚えると、H19-105_V2.0試験に参加できます。
質問 # 28
Which technologies does the Huawei FusionModule2000 use to lower PUE in a low-carbon environment?
Select all that apply
正解:A、B、C
解説:
Huawei FusionModule2000 6.0 employs three principal energy-saving technologies to improve cooling efficiency and minimize Power Usage Effectiveness (PUE): fluorine pump refrigeration, fully adaptable compressor technology, and AI-based cooling optimization.
Option A is correct because AI optimization dynamically adjusts cooling system operation according to workload and environmental conditions. Huawei identifies approximately 8% to 15% energy savings from this optimization mechanism.
Option C is correct because fluorine pump refrigeration increases the utilization of natural cooling. When the ambient temperature falls below the specified threshold, the refrigerant pump can operate without requiring the compressor, significantly reducing refrigeration energy consumption.
Option D is correct because the fully adaptable compressor improves efficiency under partial-load conditions.
By adjusting compression characteristics, the system avoids unnecessary overcompression and reduces energy consumption.
Option B is not part of the three identified technologies. The specified natural cooling method relies on refrigerant pump operation rather than direct ventilation of outdoor air into the IT environment.
These technologies collectively contribute to FusionModule2000's low-PUE performance, particularly where outdoor conditions and variable IT loads provide opportunities for energy optimization.
Huawei Training Material - Supporting Extract
Green: Three Key Technologies to Achieve the Lowest PUE.
Fluorine Pump Maximizes Natural Cooling Source.
Fully adaptable compressor, improving energy efficiency by 15%.
AI optimization, energy saving by 8 to 15%.
When the temperature is below 10°C, the fluorine pump is started and the compressor is not required to operate, greatly reducing the energy consumption.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions - Green: Three Key Technologies to Achieve the Lowest PUE. PDF page 50; slide 51.
質問 # 29
Which of the following statements correctly describe the application scenarios of the Huawei smart modular data center solution?
Select all that apply
正解:A、B、D
解説:
Huawei's smart modular data center portfolio provides standardized solutions for deployment scenarios ranging from single-cabinet edge installations to multi-cabinet enterprise facilities.
Option A correctly identifies FusionModule500 as the compact solution designed for one to two cabinets. Its specified IT load capacity is up to 3 kW per module in the product scenario overview. Typical applications include small network rooms and edge computing installations.
Option B correctly identifies FusionModule2000 as the higher-capacity solution supporting four to 48 cabinets, with an IT load capacity of up to 310 kW per module. It is suitable for branches, small and medium enterprises, and ICT equipment rooms requiring integrated infrastructure.
Option D correctly identifies FusionModule800 as supporting one to 12 cabinets, with an IT load capacity of up to 40 kW per module. It serves scenarios such as edge data centers, branch network rooms, and smaller enterprise deployments.
Option C does not correspond to the smart modular data center product lineup and capacity ranges presented in this course section.
An important specification distinction applies to A, B, and D: Huawei uses less than or equal to for the stated maximum capacities. The question's use of less than excludes the boundary value and is therefore less precise than the official specification.
Huawei Training Material - Supporting Extract
FusionModule2000: 4 to 48 cabinets; IT load of a single module # 310 kW.
FusionModule800: 1 to 12 cabinets; IT load of a single module # 40 kW.
FusionModule500: 1 to 2 cabinets; IT load of a single module # 3 kW.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions - Overview of Huawei Smart Modular DC Solution and Main Application Scenarios. PDF page 48; slide 49.
質問 # 30
True or False: Compared with a traditional switch, the load switch used in the PowerPOD 3.0 has its width reduced by 80%.
正解:A
解説:
Huawei PowerPOD 3.0 employs an innovative high-density load switch design to reduce the physical footprint of its critical power distribution architecture.
The solution uses a patented flapping-wing load switch with a compact mechanical and electrical configuration. Compared with conventional load switches, the patented design reduces switch width by approximately 80%, enabling multiple switching devices to be integrated into a smaller cabinet footprint.
This reduction is significant because traditional data center power distribution arrangements require substantial floor space for input cabinets, bypass equipment, UPS cabinets, feeder cabinets, and associated electrical components.
By integrating high-density switching technology with compact UPS power modules, PowerPOD 3.0 consolidates equipment that would otherwise occupy multiple cabinets.
Huawei's representative 2.5 MW comparison demonstrates a reduction from 21 cabinets in a conventional solution to approximately 10 cabinets in the PowerPOD 3.0 configuration. This represents a reduction of approximately 50% in the power system footprint.
The smaller switch dimensions also support a simplified physical arrangement and more efficient use of data center building space.
Option A is correct because the 80% width reduction is a specified characteristic of the patented load switch.
Huawei Training Material - Supporting Extract
Innovative load switch (Flapping-wing switch).
Built-in independent switches.
Patented small-size switch, reducing width by 80%.
1 cabinet @ 600 kVA UPS with four load switches.
Footprint saving: Converged and High-density, 21 #10 Cabinets@ 2.5 MW, Saving Footprint by 50%.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions - PowerPOD 3.0: Footprint Saving, Converged and High-Density. PDF page 18; slide 19.
Verification assessment: Direct 80% load-switch width-reduction specification.
質問 # 31
Which of the following is NOT part of the "five understandings" theoretical knowledge that an SQA (Supplier Quality Assurance) engineer is expected to master?
正解:A
解説:
Huawei's SQA professional competency framework identifies five theoretical knowledge domains required for effective safety and quality assurance within Digital Power service operations.
The first domain, Understanding of Quality System, includes knowledge of ISO 9000, Quality Management Systems (QMS), quality management principles, and engineering methodologies such as Six Sigma, Quality Control Circles (QCC), and Failure Mode and Effects Analysis (FMEA).
The second domain addresses Safety Standards of Electricity and Energy Storage, covering system-level, battery pack-level, and cell-level safety requirements, together with relevant industry standards for transportation, electrical installations, grid connection, and fire emergencies.
The third domain, Understanding of Service Business, encompasses consulting, design, engineering delivery, O & M, and the organizational boundaries between service activities and other business functions.
The remaining domains are Understanding of Basic Product Knowledge and Understanding of Typical Safety and Quality Issues.
Knowledge of competitors' quality levels may contribute to market benchmarking and improvement target setting. It is not, however, one of the five defined theoretical domains.
Option B is therefore the correct answer because it introduces a competitive benchmarking requirement rather than an established SQA knowledge category.
Huawei Training Material - Supporting Extract
Service SQA Professional Skill Requirements: Five Understandings. Understanding of Quality System; Understanding of Safety Standards of Electricity and Energy Storage; Understanding of Service Business; Understanding of Basic Product Knowledge; Understanding of Typical Safety and Quality Issues. The list does not include competitor quality-level benchmarking.
Huawei Course Reference: Partner Quality Management - Service SQA Professional Skill Requirements:
Five Understandings and Four Capabilities. PDF page 109; slide 15.
Verification assessment: Directly verified; competitive quality benchmarking is not one of the five theoretical understandings.
質問 # 32
Which of the following statements about the Huawei high-temperature chilled water fan wall are correct?
Select all that apply
正解:A、B、C
解説:
Huawei's high-temperature chilled water fan-wall solution combines electrical efficiency, modular maintenance, simplified infrastructure construction, and improved cooling performance.
Option A describes the solution's integrated Power Factor Correction (PFC) capability. Huawei's intelligent rectifier incorporates PFC technology, reducing Total Harmonic Distortion of current (THDi) to below 5% and improving power factor to above 0.99 under the stated rated-load conditions. This eliminates the requirement for a separate Active Power Filter (APF) for the specified harmonic performance. However, the term DG is not established as the component integrating PFC; the identified component is the intelligent rectifier.
Option C is correct because the fan-wall solution uses horizontal airflow distribution without requiring raised- floor construction. Removing the raised-floor requirement simplifies installation and reduces associated capital expenditure.
Option D is correct because the higher chilled-water inlet temperature, increasing from approximately 15°C to
20°C, improves cooling efficiency and reduces Cooling Load Factor (CLF) by approximately 15%.
Option B introduces an unsupported extension of the hot-swappable component list. The modular hot-swap design specifically identifies the main control board, fan driver, and low-voltage power supply. The complete fan unit is not expressly included in that one-minute hot-swap list.
Therefore, A, C, and D are the intended selections, with the component terminology in A requiring correction.
Huawei Training Material - Supporting Extract
Fan Wall High-Efficiency Cooling: 15%# CLF; inlet water temperature:15 # # 20 # ; Simplified O & M: 1min (30min # 1min); Hot-swappable module.
Integrated PFC module, THDi < 5%, PF > 0.99 @100% load. Intelligent rectifier (integrates PFC). THDi <
5%@100% load, APF is not required.
Huawei modular design (main control board/fan driver/and low-voltage power supply).
Huawei Course Reference: Fan Wall: High-Efficiency Cooling, Extraordinary Reliability, and Simplified O
& M; Integrated PFC Module; One-Side Maintenance. PDF pages 36-39; slides 37-40.