International Code Council 93-Tall-Mass-Timber-Buildings Exam Syllabus Topics:

SectionObjectives
Special Inspection Requirements- Inspector duties and responsibilities
- Inspection of connections and protective materials
- Special inspection procedures for tall mass timber buildings
Fire Protection and Fire-Resistance- Fire-resistance requirements
- Noncombustible protection and protection of mass timber elements
- Fire protection systems and related provisions
Tall Mass Timber Building Code Provisions- Mass timber materials and construction requirements
- Types IV-A, IV-B and IV-C construction
- International Building Code requirements for tall mass timber construction
Structural Inspection- Structural loads and related code requirements
- Mass timber structural elements
- Connections and fastening systems
Construction Fire Safety- Protection of mass timber during construction
- Construction-phase fire safety requirements
- International Fire Code requirements
Code Compliance and Related Requirements- Sound transmission requirements
- Energy code requirements applicable to mass timber buildings
- Documentation and verification of compliance

>> 93-Tall-Mass-Timber-Buildings測試引擎 <<

International Code Council 93-Tall-Mass-Timber-Buildings證照 & 93-Tall-Mass-Timber-Buildings題庫分享

如果你想成功通過93-Tall-Mass-Timber-Buildings認證考試,不要錯過閱讀KaoGuTi最新的93-Tall-Mass-Timber-Buildings考古題資料,100%保證通過,所有的題庫都會及時更新。使用我們軟件版本的93-Tall-Mass-Timber-Buildings題庫可以幫您評估自己掌握的知識點,從而在考試期間增加問題的回憶,幫助快速完成考試。International Code Council 93-Tall-Mass-Timber-Buildings考題具備了覆蓋率很高,能夠消除考生對考試的疑慮。93-Tall-Mass-Timber-Buildings是一個很難通過的認證考試,要想通過考試必須為考試做好充分的準備,而KaoGuTi是您最佳的選擇!

最新的 Special Inspector 93-Tall-Mass-Timber-Buildings 免費考試真題 (Q35-Q40):

問題 #35
Given: A special inspector notices on a mass timber building set of drawings a 8 in. x 8 in. solid sawn nominal dimension lumber element.
The design team has recommended the solid sawn member be replaced with an SCL element.
What minimum SCL size would be correct per the International Building Code?

答案:A

解題說明:
The IBC does not require structural composite lumber to retain the same nominal dimensions as the solid- sawn member it replaces. Instead, the minimum finished dimensions are determined from the heavy-timber dimensional equivalency provisions in Section 2304.11.
For a solid-sawn member having nominal dimensions of 8 inches by 8 inches, the corresponding minimum structural composite lumber net dimensions are 7 inches in width by 7-1/2 inches in depth. Therefore, option B is correct. The dimensional conversion recognizes that nominal solid-sawn dimensions differ from actual manufactured dimensions and that SCL products are produced to controlled net dimensions.
The 6-3/4-inch by 8-1/4-inch dimensions in option C correspond to the minimum glued-laminated timber equivalency for an 8-inch-by-8-inch nominal solid-sawn member, not the SCL equivalency. Option D incorrectly assumes that the SCL member must retain the original nominal dimensions, while option A does not match the required equivalency for either SCL or glued-laminated timber.
The substitution must also be approved by the registered design professional because dimensional compliance alone does not establish equivalent structural capacity, connection behavior, fire resistance, or load-path performance.
References/Topics: 2021 IBC Section 2304.11; heavy-timber minimum dimensions; minimum structural composite lumber net-size table.


問題 #36
Regarding water supply for the protection of buildings under construction, when combustible building materials of the building under construction are delivered to a site, the minimum fire flow provided shall be
_____ gpm.

答案:A

解題說明:
The minimum required fire flow is 500 gallons per minute. Therefore, option C is correct.
Under 2021 IFC Section 3313.2, an approved water supply must be available when combustible building materials for the building under construction are delivered to the project site. The hydrant supplying the required flow must be located within the prescribed distance of the combustible materials as measured along an approved fire apparatus access route. Where one hydrant cannot provide coverage to all combustible material locations, additional hydrants are required.
The 500-gpm requirement is the initial minimum associated with the delivery of combustible building materials. It should not be confused with the potentially greater fire-flow requirements applicable after vertical construction of a Type III, IV, or V building begins. Depending on fire separation distance and the building's calculated final fire-flow demand, a larger supply may be required under subsequent provisions.
Options A and B provide inadequate suppression capacity. Option D is not the baseline amount prescribed for the condition stated in the question. Inspectors and site safety personnel should verify that the water source is operational and accessible before substantial quantities of mass timber arrive on-site.
References/Topics: 2021 IFC Sections 3313.1 and 3313.2; construction-site water supply and combustible building materials.


問題 #37
Which of the following requires periodic special inspection of mass timber elements?

答案:A

解題說明:
Concealed connections in Type IV-C construction require periodic special inspection under 2021 IBC Table
1705.5.3, making option B correct.
The mass timber special-inspection table specifically applies to mass timber elements in Types IV-A, IV-B, and IV-C . Among the activities listed for periodic inspection are bolted connections, concealed connections, erection of mass timber construction, screw installation, verification of required predrilling, and several other connection-related installation characteristics.
Options A and C are incorrect because they specify Type IV-HT. Table 1705.5.3 is expressly scoped to Types IV-A, IV-B, and IV-C rather than Type IV-HT. Option D involves a listed Type IV-A activity, but its inspection frequency is wrong: adhesive anchors installed horizontally or upwardly inclined to resist sustained tension loads require continuous , not periodic, special inspection.
For concealed connections, inspection must occur while the relevant components remain observable. Once CLT panels, wood cover, gypsum protection, or finishes hide the connection, critical installation details may no longer be verifiable without destructive removal.
References/Topics: 2021 IBC Section 1705.5.3 and Table 1705.5.3, Required Special Inspections of Mass Timber Construction.


問題 #38
Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

答案:B

解題說明:
Option A is the exception because the base fire-resistance rating for an exterior bearing wall in Type IV-C construction is two hours, not one hour. The values are established by 2021 IBC Table 601.
Type IV-A has the most stringent tall mass timber construction requirements and assigns a three-hour rating to exterior bearing walls. Type IV-B and Type IV-C each assign a two-hour rating. Consequently, options B, C, and D accurately state the Table 601 requirements, while option A understates the required rating by one hour.
The Table 601 value is the minimum construction-type rating. Exterior bearing walls must also comply with the exterior-wall requirements of Table 705.5 based on fire separation distance. Where another code provision requires a higher rating, the more restrictive requirement governs. The inspector must therefore avoid treating the two-hour Type IV-C value as an absolute maximum.
Field verification should include the approved wall assembly, mass timber dimensions, noncombustible exterior protection, membrane continuity, protection of connections, intersections, joints, and any required opening protection. An exterior bearing wall installed as a nominal one-hour assembly would not comply merely because the timber itself has substantial cross-sectional dimensions.
References/Topics: 2021 IBC Table 601; Sections 602.4 and 705.5; exterior bearing-wall ratings for Types IV- A, IV-B, and IV-C.


問題 #39
Refer to the exhibit by clicking on the EXHIBIT button above.

Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.
The bearing area between the CLT and glulam is the minimum required.
What are the minimum dimensions, in inches, for the wood block shown in red?

答案:B

解題說明:
Under the illustrated connection detail, the minimum wood-block dimensions are 3 inches by 3 inches.
Therefore, option C is correct.
The block is part of the sacrificial wood-cover system used to protect the connection for the full two-hour fire- resistance period. It must provide sufficient timber beyond the protected connection region to account for calculated charring and the increased exposure that can develop at the interface between abutting wood members. Because the problem states that the CLT-to-glulam bearing area is already the minimum required, the primary members do not provide surplus material that can be credited as additional protection at that edge.
AWC connection-fire-design guidance requires the protective geometry to remain effective after the calculated char front advances. Char contraction can open a gap at abutting edges and expose material deeper in the connection than would occur on an uninterrupted planar surface. The 3-inch-by-3-inch block maintains the required protective envelope for the stated two-hour condition.
This dimension is specific to the illustrated configuration and assumptions; it is not a universal minimum for every mass timber connection. The inspector must verify the approved detail rather than substitute nominal blocking based solely on field availability.
References/Topics: AWC Technical Report 10; AWC Fire Design Specification provisions for wood-cover protection and char contraction at abutting members.


問題 #40
......

作為一名專業的IT人員,如何證明自己的能力,加強自己在公司的地位,獲得International Code Council 93-Tall-Mass-Timber-Buildings認證可以提高你的IT技能,以獲得更好的工作機會。快登錄KaoGuTi網站吧!這里有大量的學習資料試題和答案,是滿足嚴格質量標準的考試題庫,涵蓋所有的International Code Council 93-Tall-Mass-Timber-Buildings考試知識點。客戶成功購買我們的93-Tall-Mass-Timber-Buildings題庫資料之后,都將享受一年的免費更新服務,一年之內,如果您購買的93-Tall-Mass-Timber-Buildings學習資料更新了,我們將免費發送最新版本的到您的郵箱。