International Code Council M2 Exam Syllabus Topics:

SectionObjectives
Chimneys and Vents- Connectors and Terminations
  • 1. Termination Requirements
  • 2. Vent Connectors
- Vent Systems
  • 1. Chimney Clearances
  • 2. Vent Sizing
Hydronic Piping and Refrigeration- Hydronic Systems
  • 1. Piping Installation
  • 2. Pressure Testing
- Refrigeration
  • 1. Safety Controls
  • 2. Refrigerant Piping
General Administration- Code Scope and Administration
  • 1. Permits and Inspections
  • 2. Referenced Standards
  • 3. Definitions
Ventilation and Exhaust Systems- Ventilation
  • 1. Mechanical Ventilation
  • 2. Exhaust Air Systems
- Commercial Kitchens
  • 1. Grease Ducts
  • 2. Kitchen Exhaust Hoods
Duct Systems- Duct Construction
  • 1. Dampers and Protection
  • 2. Materials and Installation
- Air Distribution
  • 1. Plenums
  • 2. Duct Insulation
Combustion Air and Fuel Supply- Combustion Air
  • 1. Combustion Air Openings
  • 2. Indoor and Outdoor Air Requirements
- Fuel Supply Systems
  • 1. Fuel Gas Piping
  • 2. Fuel Oil Systems
Materials and Specifications- Approved Materials
  • 1. Equipment Labeling
  • 2. Installation Standards
Heating and Cooling Systems- Heating Appliances
  • 1. Furnaces
  • 2. Boilers
  • 3. Water Heaters
- Cooling Systems
  • 1. Refrigeration Equipment
  • 2. Cooling Appliances

>> International Code Council M2勉強方法 <<

一生懸命にInternational Code Council M2勉強方法 & 合格スムーズM2テスト難易度 | 検証するM2関連日本語版問題集

International Code CouncilのM2試験の準備をしていたら、PassTestは貴方が夢を実現することにヘルプを与えます。 PassTestのInternational Code CouncilのM2試験トレーニング資料は高品質のトレーニング資料で、100パーセントの合格率を保証できます。もしあなたが適当な時間を持って勉強できるのなら、PassTestのInternational Code CouncilのM2試験トレーニング資料を選びましょう。この資料を手に入れたら、楽に試験の準備をすることができます。

International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q40-Q45):

質問 # 40
An 8-inch Type B venting system with a listed vent cap must terminate a minimum of _____ feet above the flat roof through which it passes.

正解:C

解説:
For a Type B gas vent with a listed vent cap terminating through a flat roof , the minimum required termination height is 1 foot above the roof . That makes Option A correct. This is consistent with gas vent termination tables used with listed Type B vent systems and the code framework for Type B vent terminations.


質問 # 41
Exhaust outlets that terminate at a temperature exceeding 600°F shall be designed as a:

正解:D

解説:
The IMC special exhaust provisions require exhaust outlets terminating at temperatures exceeding 600°F to be designed as a chimney , and the table language identifies this as a single-wall metal chimney . Therefore, Option D is correct.


質問 # 42
Exposed solar thermal equipment protected by motor vehicle impact may be installed at what height?

正解:D

解説:
The IMC states that solar thermal equipment exposed to vehicular traffic must be installed not less than 6 feet above the finished floor . It then gives an exception stating that this requirement does not apply where the equipment is protected from motor vehicle impact . Because the height requirement is removed by that exception, the best answer from the choices given is A, directly on finished floor . This is an inference from the exception language.


質問 # 43
Pipe and duct insulation can be used within plenums except:

正解:B

解説:
For materials such as pipe and duct insulation within plenums, the IMC references ASTM E84 or UL 723 for surface-burning characteristics, along with the flame-spread and smoke-developed limits applicable to plenums. ASTM B84 is not the referenced plenum test standard here, so it is the incorrect condition and therefore the correct exam answer to the "except" question. This makes Option C correct.


質問 # 44
Infrared radiant heaters shall be installed:

正解:C

解説:
The ICC mechanical code provision for infrared radiant heaters states that the heaters must be installed with clearances from combustible material in accordance with the manufacturer's installation instructions .
That makes Option D the correct answer. The code does not establish a blanket 6-foot clearance on all sides in this section, and the exam expects the candidate to rely on the listed installation requirements for the appliance.


質問 # 45
......

International Code CouncilのM2試験トレントの指示に従って、準備期間を非常に短い時間で完了し、試験に合格することもできます。これにより、多くの時間とエネルギーを節約し、Commercial Mechanical Inspector準備トレントで生産性を高めることができます。 実際、あなたが進歩するための高効率な準備時間を保証する理由は、主に、当社PassTestのM2テストで学習プロセス中に顧客を集中させ、ターゲットを絞ることができるコンテンツとレイアウトの素晴らしい組織に起因します ブレインダンプ。 M2のCommercial Mechanical Inspector試験準備の高い合格率は99%〜100%です。