International Code Council M2 Exam Syllabus Topics:

SectionWeightObjectives
Topic 1: Fuel Supply Systems10%- Pressure regulation and overpressure protection
- Fuel gas piping materials and installation
- Piping testing and inspection
- Gas appliances and connections
Topic 2: Duct Systems12%- Dampers and access doors
- Insulation and sealing
- Duct construction and materials
- Duct installation and supports
Topic 3: General Administration18%- Code authority and enforcement
- Permits and inspections
- Manufacturer's instructions and listings
- Plan review and documentation
Topic 4: Exhaust & Ventilation Systems20%- Ventilation rates and outdoor air requirements
- Commercial kitchen exhaust systems
- Makeup air systems
- Hazardous and special exhaust systems
Topic 5: Combustion Air8%- Air supply and venting
- Confined spaces and equipment rooms
- Combustion air requirements
Topic 6: Chimneys & Vents14%- Factory-built chimneys and vents
- Chimney construction and materials
- Clearances and termination requirements
- Vent systems and connections
Topic 7: Heating, Cooling & Water Heaters18%- HVAC equipment installation and clearance
- Solar thermal systems
- Water heaters and storage tanks
- Boilers and hydronic systems
- Heat pumps and cooling equipment

>> M2問題集無料 <<

試験M2問題集無料 & 一生懸命にM2勉強資料 | 認定するM2日本語的中対策

MogiExamのInternational Code CouncilのM2試験トレーニング資料はあなたに時間とエネルギーを節約させます。あなたが何ヶ月でやる必要があることを我々はやってさしあげましたから。あなたがするべきことは、MogiExamのInternational Code CouncilのM2試験トレーニング資料に受かるのです。あなた自身のために、証明書をもらいます。MogiExam はあなたに必要とした知識と経験を提供して、International Code CouncilのM2試験の目標を作ってあげました。MogiExamを利用したら、試験に合格しないことは絶対ないです。

International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q16-Q21):

質問 # 16
Air mechanically exhausted from a room must be:

正解:D

解説:
The IMC requires air removed by a mechanical exhaust system to be discharged outdoors to an approved location and not be readily drawn back into the building. That makes D correct. The code does not permit general exhaust air to terminate in an attic, and it does not make filtering or recirculation the default rule for mechanically exhausted air.


質問 # 17
Given: An industrial water heater boiler has a manufacturer's listing of 18 inches wall clearance. It is installed with a protective wall assembly of 24-gauge sheet metal spaced out 1 inch from the wall.
The reduced installation clearance from the wall for this appliance is _____ inches.

正解:A

解説:
ICC clearance-reduction tables allow a listed clearance of 18 inches to be reduced to 9 inches where 24- gauge sheet metal is installed with a 1-inch ventilated airspace from the combustible wall. Therefore the correct answer is the option corresponding to 9 inches , which is B in your set.


質問 # 18
Where located on a roof with a 5:12 slope, a level platform shall be provided along the access panel of the furnace at least _____ inches wide.

正解:C

解説:
For appliances on roofs, ICC access provisions require a level platform at the appliance. The platform must be not less than 30 inches in any dimension . For the choices provided, that makes 30 inches the correct answer, which is Option C .


質問 # 19
All exposed gas piping shall be kept above grade a minimum of _____ inches.

正解:D

解説:
The IFGC rule for above-ground outdoor piping requires piping installed outdoors to be elevated not less than 3 1/2 inches above ground , and where installed across roof surfaces, not less than 3 1/2 inches above the roof surface . Therefore, the correct answer is A .


質問 # 20
Given: a six-story, sprinklered, multifamily building with a continuously ventilated shaft extending vertically from the first floor to the roof and used for exhaust.
Which of the following requirements must also be met?

正解:D

解説:
For this type of continuously ventilated exhaust shaft serving a multifamily building, the code requires the kitchen exhaust connection to penetrate the shaft and extend vertically not less than 22 inches without a fire damper. That matches Option D .


質問 # 21
......