Valid EDGE-Expert Study Materials | Interactive EDGE-Expert Questions

P.S. Free & New EDGE-Expert dumps are available on Google Drive shared by ExamBoosts: https://drive.google.com/open?id=14GNx85W41uLFoPLCszSbsQEe_7zzb8Bv

You may think choosing EDGE-Expert practice materials at the first time is a little bit like taking gambles. However, you can be assured by our EDGE-Expert learning quiz with free demos to take reference, and professional elites as your backup. They are a bunch of censorious elites who do not compromise on any errors happened on our EDGE-Expert Training Materials. So their accuracy rate is unbelievably high and helped over 98 percent of exam candidates pass the EDGE-Expert exam.

EDGE EDGE-Expert Exam Syllabus Topics:

SectionWeightObjectives
Topic 1: Financial & Results Analysis10%- Results and outputs of EDGE
  • 1. Baseline, utility savings, GHGs reduced
  • 2. Financial outputs in results bar
Topic 2: Water Efficiency & Materials25%- Water Demand
  • 1. Water sources (mains-supplied, recovered, recycled)
  • 2. Rainwater harvesting, recycling and other conservation techniques
  • 3. Base case water use in each building type
  • 4. Water-saving measures
- Materials Embodied Energy (EE)
  • 1. Base case definition
  • 2. Materials EE measures
Topic 3: Software & Methodology25%- Climate Zones & Weather Data
  • 1. Impact of Climate on Building Design
- Baseline & Proposed Building Models
  • 1. Proposed Design Inputs
  • 2. Basecase Definition
- EDGE Software Interface
  • 1. Data Entry Requirements
  • 2. User Interface Navigation
Topic 4: Energy Efficiency25%- Lighting & Hot Water
  • 1. Energy demand for hot water
  • 2. Energy demand for lighting
- Energy Consumption
  • 1. Energy-saving measures
  • 2. Overall energy demand of buildings
  • 3. Virtual energy for comfort
- HVAC Systems
  • 1. Technologies for Heating, Ventilation and Air Conditioning
Topic 5: EDGE System Overview15%- EDGE Certification Process
  • 1. Certification Steps
  • 2. Required Documentation
  • 3. GBCI Certification Services
- Building Types & Applicability
  • 1. Residential
  • 2. Commercial (Retail, Office, Hospital)
  • 3. Hospitality & Educational Buildings
- Understanding the EDGE Standard
  • 1. EDGE Categories (Energy, Water, Materials)
  • 2. Benefits of Green Buildings
  • 3. EDGE Certification Program

>> Valid EDGE-Expert Study Materials <<

Interactive EDGE-Expert Questions - EDGE-Expert Reliable Test Syllabus

We put high emphasis on the protection of our customers’ personal data and fight against criminal actson our EDGE-Expert exam questions. Our EDGE-Expert preparation exam is consisted of a team of professional experts and technical staff, which means that you can trust our security system with whole-heart. As for your concern about the network virus invasion, EDGE-Expert Learning Materials guarantee that our purchasing channel is absolutely worthy of your trust.

EDGE Excellence in Design for Greater Efficiencies (EDGE Expert) Exam Sample Questions (Q10-Q15):

NEW QUESTION # 10
Waste heat recovered from generators can NOT be a source of energy for

Answer: D

Explanation:
Within the EDGE framework, "waste heat recovery" from generators refers to capturing usable thermal energy from engine jacket water and exhaust gases that would otherwise be rejected to the environment. This recovered heat is a thermal resource, so it can directly serve end uses that require heat, such as space heating and domestic hot water heating. The curriculum also recognizes that recovered heat can indirectly support space cooling when it drives thermally activated cooling technologies, such as absorption chillers, where heat is used as the driving input to produce chilled water.
Mechanical ventilation, however, is fundamentally different. It is primarily an electrical end use because it relies on fans and motors to move air through ducts and provide required air changes. Thermal energy from recovered waste heat cannot power fan motors in the way electricity does. While waste heat might temper ventilation air through heat exchangers, that is not the same as being an energy source for the ventilation system itself. EDGE distinguishes between thermal end uses and electrical fan energy, so generator waste heat cannot be counted as a source of energy for mechanical ventilation.
Uploaded image


NEW QUESTION # 11
Which of the following protocols should be followed when the project city is not listed in the EDGE App?

Answer: B

Explanation:
The EDGE App relies on location-specific climate data to calculate resource savings, but not all cities are listed. The EDGE User Guide provides guidance for such cases: "If the project city is not listed in the EDGE App, the user should choose the closest city to the project location that is available in the database. If necessary, the user can edit the climate data (e.g., temperature, humidity) to better reflect the project's actual conditions, ensuring accurate calculations" (EDGE User Guide, Section 2.2: Project Setup). Option B, choose the closest city and edit the climate data if necessary, directly matches this protocol. Option A (write to EDGE Certifier and wait) is incorrect, as this is not a required step: "Users are not required to request new cities; they can proceed by selecting the closest city" (EDGE User Guide, Section 2.2: Project Setup). Option C(select any city in the same climate zone globally) is too broad and inaccurate: "Choosing a city from a different region, even in the same climate zone, may lead to incorrect assumptions about local practices and climate" (EDGE Methodology Report Version 2.0, Section 3.2: Climate Data Inputs). Option D (choose the capital city) is also incorrect unless it is the closest: "The capital city should only be selected if it is the nearest available option in the database" (EDGE User Guide, Section 2.2: Project Setup). Thus, the correct protocol is to choose the closest city and edit climate data (Option B).
Reference:EDGE User Guide Version 2.1, Section 2.2: Project Setup; EDGE Methodology Report Version
2.0, Section 3.2: Climate Data Inputs.


NEW QUESTION # 12
What is the minimum percentage of efficient lightbulbs that must be installed to claim the measure EEM22 - Efficient Lighting for Internal Areas?

Answer: B

Explanation:
The EDGE measure EEM22 - Efficient Lighting for Internal Areas focuses on reducing energy consumption through the use of efficient lighting. The EDGE User Guide specifies the requirements for this measure: "To claim EEM22 - Efficient Lighting for Internal Areas, at least 90% of the lamps in internal areas must be energy-efficient, such as LED or CFL, with a luminous efficacy of at least 80 lumens per watt. This threshold ensures significant energy savings while allowing for minimal exceptions in specific areas" (EDGE User Guide, Section 4.4: Lighting Efficiency Measures). Option C, 90%, directly matches this requirement. Option A (70%) and Option B (80%) are below the threshold, thus not qualifying for the measure. Option D (100%) exceeds the minimum requirement, but EDGE allows for flexibility with a 90% threshold to accommodate practical constraints: "A 90% requirement balances practicality with energy savings, recognizing that some areas may require specialized lighting" (EDGE Methodology Report Version 2.0, Section 5.4: Lighting Calculations). Therefore, the minimum percentage to claim EEM22 is 90% (Option C).
Reference:EDGE User Guide Version 2.1, Section 4.4: Lighting Efficiency Measures; EDGE Methodology Report Version 2.0, Section 5.4: Lighting Calculations.


NEW QUESTION # 13
Within the EDGE methodology, recycled water or rainwater harvested on site is deducted from the building's Improved Case water consumption and is reported as:

Answer: B

Explanation:
The EDGE methodology quantifies the impact of water efficiency measures like rainwater harvesting and recycled water by comparing the Improved Case to the Base Case. The EDGE Methodology Report states:
"Recycled water or rainwater harvested on site reduces the building's potable water demand in the Improved Case. This reduction is deducted from the Improved Case water consumption and reported as water savings in the EDGE software, reflecting the volume of potable water no longer required due to the measure" (EDGE Methodology Report Version 2.0, Section 4.2: Water Savings Calculations). Option B, water savings, accurately reflects this reporting method, as the software highlights the reduction in potable water use as a saving. Option A (water usage) is incorrect, as this term refers to the total consumption, not the reduction:
"Water usage in EDGE refers to the total volume consumed, not the savings achieved" (EDGE User Guide, Glossary). Option C (wastewater) is unrelated, as it refers to water output, not savings: "Wastewater is water discharged from the building, not a savings metric" (EDGE User Guide, Glossary). Option D (potable water) is also incorrect, as the measure reduces potable water use, but the reported metric is the saving, not the potable water itself: "Potable water demand is an input, while savings are the output" (EDGE User Guide, Section 5.2: Water Efficiency Measures). Thus, the correct reporting is water savings (Option B).
Reference:EDGE Methodology Report Version 2.0, Section 4.2: Water Savings Calculations; EDGE User Guide Version 2.1, Section 5.2: Water Efficiency Measures, Glossary.


NEW QUESTION # 14
What are the benefits of using a pool cover that are recognized in EDGE?

Answer: C

Explanation:
Pool covers are a water and energy efficiency measure in EDGE, particularly relevant for hotels with swimming pools. The EDGE User Guide outlines their benefits: "Pool covers reduce water demand by minimizing evaporation and energy demand by reducing the need for heating, as they retain heat in the pool.
In EDGE, the use of pool covers is recognized for its dual impact on reducing both water and energy consumption" (EDGE User Guide, Section 5.3: Additional Water Efficiency Measures). Option B, reduce both water and energy demand, directly aligns with this description. Option A (increase solar control and comfort) is incorrect, as pool covers are not recognized in EDGE for solar control or occupant comfort but for resource savings. Option C (require less maintenance and work from employees) and Option D (reduce chemical consumption and that of cleaning products) are potential secondary benefits but are not quantified or recognized in EDGE calculations, as confirmed by: "EDGE focuses on measurable water and energy savings from pool covers, not on maintenance or chemical use reductions" (EDGE Methodology Report Version 2.0, Section 4.3: Water Efficiency Calculations). Thus, Option B is the correct answer.
Reference: EDGE User Guide Version 2.1, Section 5.3: Additional Water Efficiency Measures; EDGE Methodology Report Version 2.0, Section 4.3: Water Efficiency Calculations.


NEW QUESTION # 15
......

Comparing to the training institution, our website can ensure you pass the EDGE actual test with less time and money. You just need to use spare time to practice the EDGE-Expert exam questions and remember key points of test answers. If you get a bad result in the EDGE-Expert Practice Test, we will full refund you to reduce the loss of your money.

Interactive EDGE-Expert Questions: https://www.examboosts.com/EDGE/EDGE-Expert-practice-exam-dumps.html

BTW, DOWNLOAD part of ExamBoosts EDGE-Expert dumps from Cloud Storage: https://drive.google.com/open?id=14GNx85W41uLFoPLCszSbsQEe_7zzb8Bv